检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:党会学[1,2] 赵均海[1] 张宏杰[2] 牛华伟[3]
机构地区:[1]长安大学建筑工程学院,西安710061 [2]中国电力科学研究院,北京100055 [3]湖南大学风工程试验研究中心,长沙410082
出 处:《计算力学学报》2016年第3期362-368,共7页Chinese Journal of Computational Mechanics
基 金:国家自然科学基金(51308519)资助项目
摘 要:为满足高压/特高压输电铁塔风致倒塌问题对铁塔体型系数的精准度需求,研究了完全结构化多块网格对格构式三角形输电塔塔身流场的模拟能力,探讨了不同规范体型系数对某铁塔的适用性,并分析了塔身杆件复杂流动干扰作用下的屏蔽特性。结果表明,数值模拟与风洞试验的体型系数吻合很好;完全结构化网格能高保真、高度正交地对铁塔塔身这类复杂空间桁架流场进行离散;《英国杆塔荷载规范》的规定结果虽偏于保守,但其趋势最为接近真实值;在塔身桁架结构各个杆件之间流动干扰作用下,角钢弯折角朝向来流比背向来流的屏蔽作用更强;斜材弯折角背向气流和竖向辅助材弯折角朝向气流的组合之间的流动干扰,使得其对气流的屏蔽作用最强。The crash down of transmission towers ultra towe -high r,the voltage transmission lines. Accounting applica is investigated by demands improved accuracy in wind load designing of to high fidelity simulation of flow around transmission bility of fully structured multi-block grids for solving Navier-Stokes equations enclosed by a triangular latticed tower section model k-e turbulence model, shape coefficients from different standards are compared under designing tower, and shielding effects of this section model with complex flow interference are investigated. The results indicated that, fully-structured multi-block grids exhibit high orthogonality and conform well of this complex lattice tower section model;((BS8100)) gives conservative shape coefficients while these coefficients show similar trend comparing to both wind tunnel and numerical results; Induced by flow interferences among angle-steel trusses, the angle-steel bending forward shields much more seriously comparing to that bending leeward; the combination of leeward bending diagonal member and forward bending vertical bracing member, which induce flow interference between themselves, results in the most serious shielding performance.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.229