Prediction of dispersed phase holdup in pulsed disc and doughnut solvent extraction columns under different mass transfer conditions  被引量:3

Prediction of dispersed phase holdup in pulsed disc and doughnut solvent extraction columns under different mass transfer conditions

在线阅读下载全文

作  者:Yong Wang Kathryn H.Smith Kathryn Mumford Teobaldo F.Grabin Zheng Li Geoffrey W.Stevens 

机构地区:[1]Particulate Fluids Processing Centre,Department of Chemical and Biomolecular Engineering,The University of Melbourne

出  处:《Chinese Journal of Chemical Engineering》2016年第2期226-231,共6页中国化学工程学报(英文版)

摘  要:Using experimental data from a number of pulsed disc and doughnut solvent extraction columns, a unified correla- tion for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented. Pulsed disc and doughnut solvent extraction columns (PDDC) have been used for a range of important applications such as ura- nium extraction and nuclear fuel recycling. Although the dispersed phase holdup in a PDDC has been presented by some researchers, there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction. In this study, dis- persed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland lind. Eng. Chem. Res.,27 (1988),131-138] which did not consider the effect of col- umn geometry. In order to incorporate the characteristic length of the PDDC (i.e. the plate spacing), the unified cor- relation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind. Eng. Chem. Res.,34 (1995) 3925-3940] was refitted to the PDDC data. New constants have been presented for each hold- up correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of onerating conditions and nhwical nronerties and consider the direction of mass transfer.Using experimental data from a number of pulsed disc and doughnut solvent extraction columns,a unified correlation for the prediction of dispersed phase holdup that considers the effects of mass transfer is presented.Pulsed disc and doughnut solvent extraction columns(PDDC) have been used for a range of important applications such as uranium extraction and nuclear fuel recycling.Although the dispersed phase holdup in a PDDC has been presented by some researchers,there is still the need to develop a robust correlation that can predict the experimental dispersed phase holdup over a range of operating conditions including the effects of mass transfer direction.In this study,dispersed phase holdup data from different literature sources for a PDDC were used to refit constants for the correlation presented by Kumar and Hartland [Ind.Eng.Chem.Res.,27(1988),131–138] which did not consider the effect of column geometry.In order to incorporate the characteristic length of the PDDC(i.e.the plate spacing),the unified correlation for holdup proposed by Kumar and Hartland based on data from eight different types of columns [Ind.Eng.Chem.Res.,34(1995) 3925–3940] was refitted to the PDDC data.New constants have been presented for each holdup correlation for a PDDC based on regression analysis using published holdup data from PDDCs that cover a range of operating conditions and physical properties and consider the direction of mass transfer.

关 键 词:Solvent extraction Liquid extraction Pulsed disc and doughnut columns Solvent extraction column design Holdup Dispersed phase holdup Hydrodynamics of extraction columns 

分 类 号:O658.2[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象