聚硅酸硫酸铁絮凝剂预处理高浓度化工废水的试验研究  被引量:2

Test and Study of Pretreatment of Highly Concentrated Chemical Waste Water with Polyferric Silicate Sulfate

在线阅读下载全文

作  者:王磊 

机构地区:[1]沧州渤海新区环境监测站,河北沧州061113

出  处:《化工与医药工程》2016年第3期54-57,共4页Chemical and Pharmaceutical Engineering

摘  要:采用聚硅酸硫酸铁作为絮凝剂对高浓度化工废水进行预处理,分析絮凝剂投加量、水样p H值、沉降时间对水样COD消除率的影响。试验结果表明,最佳预处理条件为絮凝剂投加量为4.0 ml/L,水样p H为9.0,沉降时间为80 min,废水水样COD消除率可达22.21%。因此,聚硅酸硫酸铁絮凝剂预处理高浓度化工废水效果明显,对于化工废水深度处理达标排放和回用具有较高的经济价值。Highly concentrated chemical waste water was pretreated by using polyferric silicate sulfate as flocculant. The quantity of flocculant needed, PH value in water sample and the effect of settle time to removal rate of COD in waste water sample were analyzed. It was shown that the optimum condition for pretreatment is as follows: the quantity of flocculant is 4.0 m/L; PH value of water sample is 9.0; when settle time is 80 min, the removal rate of COD can reach 22.21%. Thus, the effect of using polyferric silicate sulfate as flocculant is distinct in pretreatment of chemical waste water, and the method is highly valuable in extensive treatment for chemical waste water.

关 键 词:化工废水 预处理 聚硅酸硫酸铁 COD消除率 

分 类 号:X78[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象