Synthesis and properties of three novel rhodamine-based fluorescent sensors for Hg^(2+)  被引量:4

Synthesis and properties of three novel rhodamine-based fluorescent sensors for Hg^(2+)

在线阅读下载全文

作  者:Miao-Miao Hong Ai-Feng Liu Ying Xu Dong-Mei Xu 

机构地区:[1]College of Chemistry, Chemical Engineering and Materials Science, Soochow University [2]Jiangsu Key Laboratory of Advanced Functional Polymer Design and Application, Soochow University [3]Testing and Analysis Center, Soochow University

出  处:《Chinese Chemical Letters》2016年第6期989-992,共4页中国化学快报(英文版)

基  金:supported by the National Natural Science Foundation of China (No. 21074085);the Priority Academic Program Development of Jiangsu Higher Education Institutions;the Graduate Student Innovation Training Project of Jiangsu Province (No. KYLX_1241);the State and Local Joint Engineering Laboratory for Novel Functional Polymeric Materials

摘  要:Three novel rhodamine-based Hg^2+ fluorescent sensors were designed and synthesized. The sensors could work in semi-aqueous solutions with nearly neutral p H and showed high selectivity and sensitivity to Hg^2+ with remarkable fluorescence enhancement. For these three sensors, the linear working range broadened(0–80, 0–100 and 0–140 μmol/L, respectively) and the sensitivity increased(7.7, 15.5 and 17.6 folds of the fluorescence enhancement and 512, 66.2 and 37.6 ppb of the detection limit) with the rising of the thiourea-unit numbers. Furthermore the sensors exhibited excellent interference immunity to multiple environmentally and biologically relevant metal ions. Pond and tap water assay showed good practicability of the sensors. The number of the bound Hg^(2+) equaling to that of the thiourea units and the irreversible recognition process implied a new interaction way between Hg^(2+) and the sensor.Three novel rhodamine-based Hg^2+ fluorescent sensors were designed and synthesized. The sensors could work in semi-aqueous solutions with nearly neutral p H and showed high selectivity and sensitivity to Hg^2+ with remarkable fluorescence enhancement. For these three sensors, the linear working range broadened(0–80, 0–100 and 0–140 μmol/L, respectively) and the sensitivity increased(7.7, 15.5 and 17.6 folds of the fluorescence enhancement and 512, 66.2 and 37.6 ppb of the detection limit) with the rising of the thiourea-unit numbers. Furthermore the sensors exhibited excellent interference immunity to multiple environmentally and biologically relevant metal ions. Pond and tap water assay showed good practicability of the sensors. The number of the bound Hg^(2+) equaling to that of the thiourea units and the irreversible recognition process implied a new interaction way between Hg^(2+) and the sensor.

关 键 词:RHODAMINE Polyethylenepolyamine THIOUREA Fluorescent sensor Hg2+ 

分 类 号:O657.3[理学—分析化学] TP212[理学—化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象