检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]南网超高压输电公司柳州局,广西柳州545006 [2]三峡大学电气与新能源学院,湖北宜昌443002
出 处:《陕西电力》2016年第6期69-71,81,共4页Shanxi Electric Power
基 金:国家自然科学基金项目资助(51477090)
摘 要:V型绝缘子串是紧凑型输电线路的重要组成部分,能够有效地缩短串长的垂直高度以及减小导线悬挂点风偏范围。采用二分法,对V型绝缘子串的力学模型进行数值计算,研究了500 kV紧凑型线路V型串夹角变化过程中导线悬挂点水平位移、垂直位移、受压串轴向压缩量以及受压串最大应力随风速的变化关系,从控制最大应力的角度,对V型串夹角进行优化,得到V型串夹角最优值。并根据V型绝缘子串受力特点提出相关防护措施。V-type insulator string is an important part of compact transmission line which can shorten the vertical height of insulator strings and decrease the range of wind deviation.The mechanical model of V-type insulator strings is calculated by using dichotomy.The relationship among horizontal displacement,vertical displacement,axial compression amplitude,maximum stress and wind speed is studied when the included angle of 500 kV compact transmission line V-type insulator strings change.The optimization of included angle of V-type insulator strings is realized on the consideration of controlling maximum stress and the optimum value of included angle of V-type insulator strings is obtained.Related protection measures are put forward.
关 键 词:紧凑型线路 V型绝缘子串 二分法 受力特性 夹角优化 安全防护
分 类 号:TM75[电气工程—电力系统及自动化]