1000MW机组未投RB功能时单台给水泵跳闸故障处理  被引量:4

Fault Treatment of Single Pump Trip on 1000 MW Unit While RB Function not Running

在线阅读下载全文

作  者:包有超 

机构地区:[1]广东粤电靖海发电有限公司,广东揭阳515223

出  处:《内蒙古电力技术》2016年第3期68-73,77,共7页Inner Mongolia Electric Power

摘  要:在RB功能不完善的条件下,某电厂1000 MW超超临界机组满负荷时发生1起单台给水泵的跳闸故障。处理时将机组主控切至TF模式,手动调节各主要参数,并严格执行主要参数调整不超限,防止发生锅炉MFT,稳定控制给水流量,严格控制水煤比,严防小机超速及高压加热器跳闸等控制要点,使机组负荷、调节阀开度、主汽压力等参数平稳下降,机组给水流量易于调节,顺利完成了机组负荷从1000 MW迅速减至500 MW的调节控制过程,最终使各机组恢复到正常运行状态,保证了机组的安全稳定运行。Under the condition that the RB function was not put into operation, the tripping fault of single feed water pump occured on the 1000 MW ultra supercritical unit while in full load in a power plant. By cutting to the TF mode when dealing with the masters, through manual adjustment of the main parameters, and strictly enforced the main parameters adjustment not to exceed the limit, prevented the occurrence of boiler MFT, stability controlled water flow, strictly controlled the ratio of coal to water, prevented small steam turbine speed and high pressure heater tripping etc. control points, made the unit's load, regulating valves opening, and the main steam pressure parameters decline steadily, unit feed water flow was easy to adjust, smoothly completed the controlling process that the unit load quickly reduced from 1000 MW to 500 MW, ultimately enable the unit returned to the normal operating state, ensured the safe and stable operation of the unit.

关 键 词:1000 MW超超临界机组 RB TF模式 给水泵跳闸 水煤比 

分 类 号:TM621.7[电气工程—电力系统及自动化]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象