检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:梁坚豪[1] 朱新进[1] 刘杰[1] 谭志成[1]
机构地区:[1]南方医科大学附属佛山医院佛山市第二人民医院影像中心,广东佛山528000
出 处:《实用放射学杂志》2016年第7期1116-1118,共3页Journal of Practical Radiology
摘 要:目的:探讨多层螺旋 CT 低剂量扫描技术在甲状腺增强扫描中的临床应用价值。方法80例患者随机分为4组(每组各20例),4组分别为:A 组,120 kV、180 mA;B 组,120 kV、100 mA;C 组,100 kV、180 mA;D 组,100 kV、100 mA。主观评价图像质量并评分,统计甲状腺 CT 值、图像背景噪声(N)、图像信噪比(SNR)、CT 剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)并进行对比分析。结果4组图像主观评分为3.90±0.31、3.75±0.44、3.70±0.47、3.60±0.60,SNR 为26.34±3.13、25.08±1.87、25.86±2.38、24.87±2.20,四者无统计学差异(P 〉0.05);甲状腺 CT 值为(168.55±13.39)HU、(170.70±11.34)HU、(185.20±22.35)HU、(190.55±21.38)HU,N 为(6.48±0.84)HU、(6.83±0.45)HU、(7.19±0.86)HU、(7.66±1.01)HU, CTDIvol 为(10.95±0.00)mGy、(6.08±0.00)mGy、(6.59±0.00)mGy、(3.66±0.00)mGy,DLP 为(145.67±8.79)mGy·cm、(84.58±4.94)mGy·cm、(89.86±3.26)mGy·cm、(50.20±1.89)mGy·cm,ED 为(0.73±0.04)mSv、(0.42±0.03)mSv、(0.45±0.03)mSv、(0.25±0.01)mSv,四者有统计学差异(P 〈0.05)。结论多层螺旋 CT 低剂量扫描技术既能保证图像质量又能有效降低甲状腺增强 CT 检查的辐射剂量。Objective To evaluate the value of multi-slice spiral CT Low-dose scanning technology in thyroid enhanced scan. Methods Eighty patients were randomly divided into four groups including Group A:120 kV,180 mA;Group B:120 kV,100 mA;Group C:100 kV,180 mA and Group D:100 kV,100 mA.The subjective image quality was evaluated and scored.Thyroid CT val-ue,image background noise (N),image signal to noise ratio (SNR),CT dose index (CTDIvol),dose length product (DLP),and the effective radiation dose (ED)were measured and compared.Results The subjective image scores and SNR of these four groups were 3.90±0.31 and 26.34±3.13,3.75±0.44 and 25.08 ±1.87,3.70 ±0.47 and 25.86 ±2.38,3.60 ±0.60 and 24.87 ±2.20 respectively.There were no significantly statistical differences among the subjective image scores and SNR (P 〉 0.05 )of the 4 Groups.Thyroid CT values,N,CTDIvol,DLP and ED were (1 68.55 ± 13.39)HU,(6.48 ±0.84)HU,(10.95 ±0.00)mGy, (145.67±8.79)mGy·cm,(0.73±0.04)mSv in Group A,(170.70±11.34)HU,(6.83±0.45)HU,(6.08±0.00)mGy,(84.58± 4 .9 4)mGy· cm,(0 .4 2 ±0 .0 3 )mSv in Group B,(1 8 5 .2 0 ±2 2 .3 5 )HU,(7 .1 9 ±0 .8 6 )HU,(6 .59 ±0 .00 )mGy,(89 .86 ± 3 .26 )mGy· cm,(0 .45 ±0 .03 )mSv in Group C,(190 .55 ±21 .38 )HU,(7 .66 ± 1 .01 )HU,(3 .66 ±0 .00 )mGy,(50 .2 0 ± 1 .89 )mGy·cm,(0.25±0.01)mSv in Group D respectively.There were significantly statistical differences among different thyroid CT values,N,CTDIvol,DLP and ED (P 〈0.05).Conclusion Multi-slice spiral CT low-dose scanning technology in thyroid en-hanced scan can guarantee the image quality and effectively reduce thyroid radiation dose.
分 类 号:R814.42[医药卫生—影像医学与核医学] R322.51[医药卫生—放射医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249