扰流孔强化波纹板蓄热元件传热性能的实验研究  被引量:2

Experimental Study on Heat Transfer Enhancement of Corrugated Plate by Staggered Perforations

在线阅读下载全文

作  者:李鹏程[1] 孙志坚[1] 黄浩[1] 汤舟[1] 胡亚才[1] 

机构地区:[1]浙江大学热工与动力系统研究所,杭州310027

出  处:《动力工程学报》2016年第7期530-534,共5页Journal of Chinese Society of Power Engineering

基  金:金华市科学技术研究计划重点资助项目(20131031)

摘  要:采用瞬态实验方法研究了3种排列角度(15°、30°和45°)下的扰流孔波纹板蓄热元件的传热性能,并比较了等效泵功下的Nu/Nu_o*值.结果表明:与未添加扰流孔的波纹板蓄热元件相比,3种排列角度下的带扰流孔的波纹板蓄热元件的平均Nu分别提高了17.1%、24.8%和34.9%;3种情况下的平均阻力因数f分别提高了24.7%、33.1%和38.4%;与排列角度为30°和15°相比,45°时的Nu/Nu_o*分别提高了53.3%和67.8%,表明扰流孔排列角度为45°时,波纹板蓄热元件具有最佳性能.Transient test method was used to study the heat transfer performance of corrugated plate with staggered perforations in different arrangements (15°, 30° and 45°) , and to compare the value of Nu/Nu. * at equal pumping power. Results show that compared with corrugated plates without perforations, the average Nu of the plate with staggered perforations in above three arrangements is increased by 17. 1%, 24.8% and 34.9% respectively, with an increase of friction factor f by 24.7%, 33.1% and 38.4% accordingly. Compared with the arrangements of 15° and 30°, the value of Nu/Nu.* in the case of 45° is correspondingly increased by 53.3% and 67.8%, indicating that the heat transfer performance of corrugated plate reaches the maximum in the arrangement of 45°.

关 键 词:扰流孔 波纹板蓄热元件 强化传热 传热性能 实验研究 

分 类 号:TK124[动力工程及工程热物理—工程热物理]

 