检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]国网北京市电力公司电力科学研究院,北京100075 [2]安徽大学教育部电能质量工程研究中心,安徽合肥230601
出 处:《电器与能效管理技术》2016年第13期63-66,71,共5页Electrical & Energy Management Technology
摘 要:针对某低压台区3次谐波超标问题,进行电能质量测试。在实测数据的基础上,通过负序和谐波电压电流测试数据估算系统阻抗,零序电压电流测试数据估算零序阻抗,将估算结果进行对比和分析,说明该台区3次谐波产生的机理,并给出相应的解决方案。Aiming at the overproof problem of 3th harmonic in a low voltage area,power quality of the low voltage area was tested. On the basis of the measured data,the system impedance was estimated by the voltages and currents of negative sequence and harmonic,and the zero sequence system impedance was estimated by the zero sequence voltages and currents,and then the estimated results were compared and analyzed,showing the mechanism of 3th harmonic. At last the solutions were given.
分 类 号:TM761[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222