检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:刘军[1,2] 闫红岭[1,2] 连文莉[1,2] 陈浩凤[1,2] 王琳[1,2] 于亚辉[1,2]
机构地区:[1]河南省岩石矿物测试中心,河南郑州450012 [2]国土资源部贵金属分析技术重点实验室,河南郑州450012
出 处:《冶金分析》2016年第7期25-33,共9页Metallurgical Analysis
基 金:省两权价款(豫国土资函[2014]90号-3)
摘 要:通过高压密闭溶解样品,建立了一次溶解样品后直接用电感耦合等离子体质谱法(ICP-MS)对地质样品中Au、Ag、Pt、Pd进行测定的方法。实验表明,于200mL的高压密闭溶样罐中加入10.00g样品后,通过加入30mL HCl、5.0mL H2O2、2.0g KClO3,及在160℃的恒温数显鼓风干燥箱中保温6h,可将地质样品溶解完全;将样品消解液用由活性炭、改性活性炭、717阴离子交换树脂组合而成的新型组合富集剂分离富集及通过选择合适的测定同位素或数学校正方法消除质谱干扰后,可实现ICP-MS对地质样品中Au、Ag、Pt、Pd的测定;Au、Ag、Pt、Pd的校准曲线相关系数均不小于0.999 5,方法检出限分别为Au 0.097ng/g、Pt 0.14ng/g、Pd 0.17ng/g、Ag 0.082ng/g。将实验方法应用于铂族元素地球化学一级标准物质中Au、Ag、Pt、Pd的测定,结果与认定值相符,12次测定的相对标准偏差(RSD)不大于14.2%,将实验方法应用于地球化学一级标准物质和实际样品中Au、Ag、Pt、Pd的测定,回收率为92%~110%,After the sample was dissolved in high pressure sealed system,a direct determination method of Au,Ag,Pt and Pd in geological samples was established by inductively coupled plasma mass spectrometry(ICP-MS).The experimental results showed that,10.00 g of geological samples could be fully dissolved by adding 30 mL of HCl,5.0mL of H2O2 and 2.0g of KClO3 in 200mL high pressure sealed tank,which was put in constant temperature digital drying oven at 160 ℃for 6h.The sample digestion solution was separated and enriched with novel composite adsorbent composed of activated carbon,modified activated carbon and 717 anion exchange resin.Then the mass spectrometry interference was eliminated by selecting proper isotopes or mathematic correction.Consequently,the determination of Au,Ag,Pt and Pd in geological samples was realized by ICP-MS.The correlation coefficients of calibration curves of Au,Ag,Pt and Pd were not less than 0.999 5.The detection limit of Au,Ag,Pt and Pd was 0.097,0.14,0.17and0.082ng/g,respectively.The proposed method was applied to the determination of Au,Ag,Pt and Pd in geochemical primary reference materials of platinum family element,and the results were consistent with the certified values.The relative standard deviation(RSD,n=12)was not more than 14.2%.The experimental method was applied to the determination of Au,Ag,Pt and Pd in geochemical primary reference materials and actual samples,and the recoveries were between 92% and 110%.
关 键 词:封闭溶矿 电感耦合等离子体质谱法(ICP-MS) 地质样品 活性炭 改性活性炭 717阴离子交换树脂 金 银 铂 钯
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222