光伏方阵串并联失配损失的测试与分析  被引量:5

Test and analysis of the loss of PV array parallel connection

在线阅读下载全文

作  者:董双丽 刘书强 林荣超 曾飞 胡振球 

机构地区:[1]广东产品质量监督检验研究院,广东佛山528300

出  处:《电子测试》2016年第7期129-130,共2页Electronic Test

摘  要:本文总结了一套光伏方阵串并联失配损失的测试方法 ;以广东某5.5MWp分布式光伏发电系统为例,现场抽测了4组20块组件串联成为一个组串后的串联失配损失和10个组串并联接入一台汇流箱后的并联失配损失,最大值分别为1.64%和0.92%,证实了此方法的可操作性;对结果进行分析,提出了减小串并联失配损失的方法,对提高光伏发电系统的发电量具有重要意义。This paper summarizes a set of photovoltaic array series parallel test method of loss distribution;in Guangdong,a 5.5MWp distributed photovoltaic power generation system as an example,on-site sampling tests and 4 groups of 20 pieces of components are connected in series into a group on the series lost with loss and 10 groups on parallel access to a junction box after the parallel mismatch loss,maximum value respectively 1.64% and 0.92%, confirmed the this method of operation;to analyze the results of the proposed decrease on parallel loss of loss distribution approach,and it has important significance to improve the photovoltaic power generation system of generating capacity.

关 键 词:光伏发电系统 串并联失配 测试 减小措施 

分 类 号:TM615[电气工程—电力系统及自动化]

 