局部热处理对TA1钛合金-SPCC钢压印接头失效行为的影响  

Influence of Local Heat Treatment on Failure Behavior of TA1 Titanium Alloy-SPCC Steel Clinched Joint

在线阅读下载全文

作  者:王医锋 何晓聪[1] 曾凯[1] 卢毅[1] 王玉奇[1] 

机构地区:[1]昆明理工大学机电工程学院,昆明650500

出  处:《机械工程材料》2016年第8期86-89,共4页Materials For Mechanical Engineering

基  金:国家自然科学基金资助项目(50965009);昆明理工大学分析测试基金资助项目(20140974)

摘  要:在自行搭建的局部热处理试验平台上将TA1钛合金-SPCC钢压印接头连接部位加热至900℃水淬,研究了局部热处理对此压印接头失效载荷和失效模式的影响。结果表明:局部热处理后该压印接头的失效载荷为5 371.9N,比未经热处理的(4 252.4N)提高了26.34%;未经热处理压印接头的失效模式为上下板拉脱失效,断裂方式为韧性断裂,局部热处理后该压印接头的失效模式为拉脱+颈部断裂混合失效,断裂方式为准解理断裂。The connection part of TA1 titanium alIoy-SPCC steel clinched ioint was heated to 900 ℃ then water quenched on the self-designed experimental platform. The influences of the local heat treatment on the failure load and failure mode of the clinched joint were investigated. The results show that the failure load of the clinched joint after local heat treatment was 5 371.9 N, which was improved by 26.34% comparing to 4 252.4 N before local heat treatment. The failure mode of the clinched joint before local heat treatment was a pull-off failure between upper and lower plate and the fracture mode was ductile fracture. After local heat treatment, the failure mode of the clinched joint was a mixture failure of pull-off and neck breaking and the fracture mode was quasi-cleavage fracture.

关 键 词:局部热处理 压印接头 失效载荷 失效模式 断口形貌 

分 类 号:TG3[金属学及工艺—金属压力加工]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象