毛细管柱气相色谱法同时测定工作场所空气中环己酮和异佛尔酮  被引量:3

Simultaneous Determination of Cyclohexanone and Isophorone in the Air of Workplace

在线阅读下载全文

作  者:彭书萍 鲍林 蔡卓弟 

机构地区:[1]广东安源鼎盛检测评价技术服务有限公司,广东东莞523000 [2]东莞市化工学会,广东东莞523000

出  处:《广东化工》2016年第15期289-290,共2页Guangdong Chemical Industry

摘  要:目的建立优化工作场所空气中环己酮和异佛尔酮同时测定的气相色谱法。方法采用活性炭管采集,二硫化碳解吸后,使用CNW-WAX毛细管柱(30m×0.25min×0.25μm)分离,氢火焰离子化检测器,气相色谱法同时测定工作场所空气中环己酮和异佛尔酮。结果环己酮的检出限为0.04μg/mL,相关系数为0.9998,相对标准偏差(RSD)2.3%-4.7%,回收率95.5%-99.0%;异佛尔酮的检出限为0.03μg/mL,相关系数为0.9999,回收率95.7%~97.9%,相对标准偏差为1.4%~3.9%。结论该方法灵敏、准确、操作性强,可提高工作效率,适用于工作场所空气中环己酮和异佛尔酮的同时监测。Objective To establish a method for Simutaneous determination of Cyclohexanone and Isophorone in the air of workplace. Methods Organic compounds were collected with charcoal tubes, by using of CNW-WAX (30 m×0.25 min×0.25 μm)capillary column and by drogen flame ionization detector, then detected by gas chromatography after being desorbed with carbon disulfide. Results The method of the limits of detection Cyclohexanone was 0.04 μg/mL, Isophoron was 0.03 μg/mL, the correlation coefficients were 0.9998-0.9999, the average recoveries were 1.4 %-4.7 %, and the recovery rates were 95.5 %-99.0 %. Conclusioa The method is sensitive, accurate, operational, and has improved efficiency, so it is suitable for routine daily monitoring.

关 键 词:毛细管气相色谱法 工作场所空气 环己酮 异佛尔酮 同时测定 

分 类 号:TQ[化学工程]

 