检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑建国[1,2] 羊群芳[1,2] 刘争宏[1,2] 于永堂[1,2] 杜伟飞[1,2] 陈小三[1]
机构地区:[1]机械工业勘察设计研究院有限公司,陕西西安710043 [2]陕西省特殊土工程性质与处理技术重点实验室,陕西西安710043
出 处:《岩石力学与工程学报》2016年第8期1697-1704,共8页Chinese Journal of Rock Mechanics and Engineering
基 金:国家科技支撑计划项目(2013BAJ06B00)~~
摘 要:EDG无核密度仪是一种无损快速的压实土干密度测试仪器,其在国内的应用经验较少。为研究EDG法干密度测试的准确性和适宜性,从EDG的测试机制出发,基于黄土试样的EDG法、灌砂法和烘干法测试结果,分析EDG法干密度测试产生误差的原因,以及测试误差大小。结果表明土的复合阻抗和电容电阻比均受密度和体积含水量两者的影响是造成EDG法测试产生误差的原因;EDG法干密度测试的误差大小并不是恒定值,而是在某些特定含水率和干密度区间内测试误差较小,其他区间测试误差较大;保证土料的均匀性,控制土料的含水率在较小区间内变化是EDG法干密度测试适用的前提条件;工程实践中宜针对采用的标定模型进行测试误差分析,明确标定模型适用的含水率和干密度范围。Electronic density gauge(EDG) is a test instrument which could determine the dry density quickly and nondestructively. However the domestic application experience is rare. The measured results of loess with good homogeneity using the sand cone method,the oven-drying method and EDG were analyzed and the reasons causing the errors in EDG were found,so that the accuracy and the applicability of EDG in determining the dry density were determined. The impedance and the ratio of the capacitance over the resistance were all influenced by the density and the volumetric moisture,which was found to be the main reason causing the measurement error of EDG. The error varied with the dry density and water content. The error was smaller when the dry density and water content of the sample were within a particular range. Outside the range,the error was larger. Keeping the soil uniformity and moisture content changing within a small range are the premise of guaranteeing the accuracy of EDG measurement. It is necessary to analyze the error distribution of the soil model used in practice,and to confirm the application scope of dry density and water content to ensure a small error.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.15