摘 要:变电站每年有大量的报废蓄电池,这些报废的蓄电池加大了环境处理压力并污染地下水资源,造成巨大经济浪费。本文根据变电站直流系统中蓄电池的重要作用,分析目前变电站蓄电池运行、维护及在线监测装置的使用现状,提出了变电站蓄电池在线检测、修复系统。该系统具有日常维护检测、在线充放电、在线去硫化修复、综合分析、智能管理、自动报警等功能,在保证系统安全可靠运行的前提下提升了蓄电池的性能。Every year,a large number of used batteries in the substations will increase environmental pressures and pollute groundwater resources,causing an immense waste in the economy.In this paper,based on the important role of storage batteries in substation DC systems,the current status of the battery operation and maintenance and the usage of online monitoring devices are analyzed,so an on-line inspection and repair system for substation batteries is proposed.The system has the functions of daily maintenance detection,online charging and discharging,online desulphurization repair,comprehensive analysis,intelligent management,automatic alarm and so on.On the premise of ensuring safe and reliable operation,the system can improve the performances of the batteries.
关 键 词:变电站 直流系统 废蓄电池 在线检测 在线去硫化修复 远程智能放电