机构地区:[1]山西中辐核仪器有限责任公司,太原030006
出 处:《核电子学与探测技术》2016年第3期279-282,共4页Nuclear Electronics & Detection Technology
摘 要:为满足用同一放射性区域监测系统监控高低剂量率的需求,研制了一套宽量程放射性区域监测系统。该系统采用2支不同量程的G—M管切换技术进行区域辐射监测,实现了1×10^-7-1Gy/h宽量程放射性区域监控。测试结果表明:该系统测量0.5txGy/h时,其相对标准偏差不大于2%;测量1Gy/h时,其相对标准偏差不大于0.5%;系统长期稳定性优于1.5%,可有效地满足区域辐射监测需求。This paper introduces a method which can measure radiation in a wide range by the GM tube with 2 different measuring ranges, and develops an area monitoring equipment which can measure the radiation be- tween 1 x 10-7 - 1 Gy/h. The result shows that the system can effectively measure: the relative standard devia- tion is less than 2% when the ambient dose equivalent get 0.5μGy/h ; the relative standard deviation is less than 0.5% when the ambient dose equivalent get 1 Gy/h; System stability is better than 1.5%
分 类 号:TL818[核科学技术—核技术及应用]