BF1-110频率继电器屡次烧损之原因分析  被引量:2

Analysis of Reasons for Repeated Burn of Frequency BF1-110 Relay

在线阅读下载全文

作  者:尤家安 

机构地区:[1]中冶集团铜锌有限公司巴基斯坦.山达克铜金项目,北京100028

出  处:《电气技术》2016年第8期122-125,共4页Electrical Engineering

摘  要:本文对BF1-110型频率继电器的触点屡次烧损故障,经过检查相关元件,根据现场故障现象,通过反复试验和全面分析,针对跳闸铁心动作异常,分解后发现内部存有油泥状粘稠物,以及频率继电器触点容量不够,从而确定了频率继电器被烧的原因和改进措施,为从事该项工作的检修技术人员提供了来自现场的第一手经验参考。In view of repeated burns on contact spot of Frequency BFI-llO Relay, based on its failure appearance, by examining relative component, conducting repetitive tests, and making comprehensive analysis, this paper focuses on the abnormity in the act of tripped iron core. With a thought given to the grease-like sticky things found inside the core and the insufficient capacity in the relay contact spot, the reason and improvement measures for the burns are finalized, providing a first-hand reference for technical repairmen in this field.

关 键 词:频率继电器 跳闸线圈 跳闸铁心 跳闸顶杆 低频 脱扣连扳 触点粘连 跳闸拒动 

分 类 号:TM58[电气工程—电器]

 