检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张卓然[1] 梁福来[2] 李浩楠[3] 吕昊[2] 祁富贵 安强[2] 王健琪[2]
机构地区:[1]第四军医大学学员一旅四营十六连,西安710032 [2]第四军医大学生物医学工程学院医学电子学教研室,西安710032 [3]第四军医大学学员一旅二营五连,陕西西安710032
出 处:《中国医疗设备》2016年第9期29-33,共5页China Medical Devices
基 金:国家科技支撑计划(2014BAK12B02);国家重大科研仪器设备研制专项(61327805);陕西省自然科学基金(2014JQ2-6034)
摘 要:生物雷达是以探测生命体为目标的新概念雷达。静止人体的生命体征由于障碍物的衰减作用,呈现信号微弱、受环境杂波干扰较大的特点,这就使生物雷达对人体目标的探测性能降低。本研究采用双通道步进频率连续波(SFCW)雷达改善该问题,首先建立生命体征信号的SFCW回波模型,然后分析SFCW雷达参数对探测性能的影响,最终提出了基于双通道SFCW生物雷达的静止人体目标探测方法。本方法首先利用预处理去除系统和传输信道引入的干扰,然后通过通道间相干处理进一步抑制环境杂波,最后利用CFAR检测器、形态学滤波和聚类算法对生命体进行探测与定位。实测数据处理结果表明,双通道SFCW生命探测雷达系统可有效去除杂波干扰,实现人体目标的高性能探测与定位。Bio-radar, which is aimed at detection of vital signs, is an emerging concept. The vital sign of static human becomes weak and easily interfered by the surrounding environment due to the attenuation of the obstacles, which makes it difficult for bio-radars to obtain the high performance in detection of static human body. Dual-channel SFCW(Stepped-Frequency Continuous Wave) radar is used to improve this problem in this paper. The dual-channel SFCW echo model of vital signs are established firstly, and then the influence of the SFCW radar parameter on the detection performance is analyzed. On this basis, a new method of static human body detection based on dual-channel SFCW radar is proposed. In this method, preprocessing is used to suppress interference, and then dual-channel coherence is adopted to further suppress environmental clutter. The CFAR detector, morphological filtering and clustering are applied in detection and localization of static human. Experimental results show that the proposed method can effectively suppress clutter and improve the detection performance.
分 类 号:R318.6[医药卫生—生物医学工程] TN95[医药卫生—基础医学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222