检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:袁宗保[1]
出 处:《洁净与空调技术》2016年第2期31-34,共4页Contamination Control & Air-Conditioning Technology
摘 要:要云南省七彩云南·古滇王国大剧院项目冷热源采用风冷螺杆式冷热水机组;空调水系统采用二管制异程式系统;舞台、观众厅、排练厅及咖啡厅等均采用全空气系统,办公、化妆间等空间采用风机盘管加新风系统;机械控制间、消防控制室、信号机房、音响室、功放房等设置独立的变制冷剂流量的空调系统。介绍了该剧院空调冷热源的配置,主要功能区的空调系统以及通风防排烟系统的设计情况。In this project, we use the air cooled screw type heat pump units as the heating and cooling source. The airconditioning water system adopt two-pipe system. We design the all-air systems for stage, auditorium, rehearsal rooms and cafe, install fan-coil and fresh air system for the small rooms such as offices and dressing rooms and adopt variable refrigerant volume system for mechanical control rooms, fire control rooms, signal control rooms, acoustic rooms and power amplifier rooms. This paper gives an introduction on the design of heating and cooling sources, air conditioning systems of typical zones, ventilation and smoke control systems in this project.
关 键 词:冷热源 全空气系统 风机盘管-新风系统 变制冷剂流量空调系统 防排烟
分 类 号:TU834[建筑科学—供热、供燃气、通风及空调工程]