25Hz交流二元继电器理想相位角实验室测量方法  

Laboratory Method for Measuring the Ideal Phase Angle of 25 Hz AC Two-element Relays

在线阅读下载全文

作  者:王会娟 

机构地区:[1]西安全路通号器材研究有限公司,陕西西安710100

出  处:《铁道技术监督》2016年第9期24-26,共3页Railway Quality Control

摘  要:介绍25 Hz交流二元继电器的基本特征,讨论其理想相位角随轨道线圈电压值动态变化的原理。针对理想相位角的测试难点,研究实验室适用的反推逼近测量方法,找到轨道线圈电压与相位角的关系,逐步调试出相位角临界点,进而计算出理想相位角。解决了因轨道线圈电压值设置不同而影响理想相位角测试结果的问题。The article introduces the essential features of 25 Hz two-element relays,discussing the principle that its ideal phase angle changes dynamically with the voltage value of rail coils. With a view to the difficulty in testing the ideal phase angle,it studies the inverse approximation method proper for laboratories. It clearly states that it shall find the relationship between the voltage of rail coil and the phase angle,gradually work out the critical point for phase angle and then calculate the ideal phase angle. The article solves the problem that various voltage settings of rail coil can affect the test result of ideal phase angle.

关 键 词:交流二元继电器 理想相位角 轨道线圈电压 测量 

分 类 号:U284.2[交通运输工程—交通信息工程及控制]

 