检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]厦门南磁电子有限公司,福建厦门361100 [2]中国电子科技集团公司第九研究所,四川绵阳621000
出 处:《磁性元件与电源》2016年第10期121-125,共5页Components and Power
摘 要:高频电子变压器及电感器是开关电源中的重要组成部分,它的功率损耗约占电源总损耗的30%,因而此部分功率损耗的大幅度降低可以提高开关电源的性能。基于脉冲变压器的原理,就UUI磁芯和传统EE型磁芯中柱开隙磁件的功率损耗进行定性比较分析,结果表明开关电源采用UUI磁芯电子变压器时,变压器本身的功率损耗可以降低20%。High frequency magnetic units (electronic transformers and inductors) are important components in switching power supply, and it accounts for about a third of power loss in overall power loss. Thus, amount of reduction in magnetic unit power loss can greatly increase the efficiency of switching power supply. Based on theory of pulse transformer, this article compared and analyzed the power loss of UUI and EE magnetic units. The result suggests that the power loss of electronic transformer had a 20% reduction for switching power supply using UUI core transformer.
关 键 词:UUI磁芯 EE型磁芯 电子变压器 电感器 功率损耗
分 类 号:TM923.328[电气工程—电力电子与电力传动]