检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:陈波[1] 徐明敏[1] 赵永纲[2,3] 金米聪[2,3]
机构地区:[1]宁波市北仑区疾病预防控制中心,浙江宁波315800 [2]宁波市疾病预防控制中心浙江省微量有毒化学物健康风险评估技术研究重点实验室,浙江宁波315010 [3]宁波市疾病预防控制中心宁波市毒物研究与控制重点实验室,浙江宁波315010
出 处:《中国卫生检验杂志》2016年第19期2747-2750,共4页Chinese Journal of Health Laboratory Technology
基 金:宁波市自然科学基金项目(2014A610283);宁波市科技惠民项目(2015C50041);浙江省公益性技术应用研究计划项目(2015C31149);浙江省微量有毒化学物健康风险评估技术研究重点实验室开放基金(2014003)
摘 要:目的建立一种快速、高效、准确的同时测定环境水中12种致敏性分散染料的磁性碳纳米管-分散固相萃取-超快速液相色谱(d SPE-UFLC)方法。方法环境水采用氨基修饰磁性碳纳米管对12种致敏性分散染料进行-分散固相萃取技术富集,采用Shim-pack XR-ODSⅡ(75 mm×2.0 mm,2.2μm)和Shim-pack XR-ODSⅢ(75 mm×2.0 mm,2.2μm)双柱串联,以0.02 mol/L乙酸铵水溶液(内含0.08%甲酸)和乙腈(内含0.1%甲酸)为流动相,梯度洗脱,全波长(190 nm^700 nm)检测。结果 12种致敏性分散染料的浓度为1.00μg/L^500μg/L时,线性关系良好(r≥0.997 4),检出限为0.082μg/L^1.49μg/L,最低定量限为0.27μg/L^4.92μg/L,RSD为2.6%~8.2%;在低、中、高3种加标水平下,回收率分别为76.2%~100%、80.6%~98.4%、79.2%~98.9%。磁性碳纳米管的富集倍数为100倍。结论本法可用于环境水样中上述12种致敏性分散染料的快速测定。Objective To develop a rapid,effective and accurate method for the simultaneous determination of 12 allergenic disperse dyes in environmental water sample by carbon nano-tube-dispersive soild phase extraction-ultra fast liquid chromatography-diode array detection( CNTs-d SPE-UFLC-DAD). Methods The 12 allergenic disperse dyes in the environment water were enriched by amino-functionalized magnetic CNTs-dispersive solid phase extraction. Chromatographic separation was performed on Shim-pack XR-ODSⅡ( 75 mm × 2. 0 mm,2. 2 μm) and Shim-pack XR-ODSⅢ( 75 mm × 2. 0 mm,2. 2 μm) columns. With 0. 02 mol / L ammonium acetate solution( containing 0. 08% formic acid) and acetonitrile( containing0. 1% formic acid) as mobile phases for gradient elution,the 12 allergenic disperse dyes were detected at full wavelength( 190 nm-700 nm). Results Good linearity was obtained when the concentration of 12 allergenic disperse dyes was within1. 00 μg / L-500 μg / L,with the determination coefficients( r ≥ 0. 997 4). The limits of detection( LODs) were within0. 082 μg / L-1. 49 μg / L,and the limits of quantification( LOQs) were within 0. 27 μg / L-4. 92 μg / L. The relative standard deviations( RSDs) were within 2. 6%-8. 2%. Recoveries were within 76. 2%-100%,80. 6%-98. 4% and 79. 2%-98. 9% at the low,medium and high spiked levels,respectively. And the enrichment times of magnetic carbon nanotubes was100. Conclusion The developed method can be applied to the routine analyses for the determination of 12 allergenic disperse dyes in environmental water samples.
关 键 词:超快速液相色谱-二极管阵列检测法 分散固相萃取 碳纳米管 致敏性分散染料 环境水样
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.225