检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:候华毅 董美丽[1,3] 王贻坤[1,3] 朱灵[1,3] 马祖长[1] 刘勇[1,3]
机构地区:[1]中国科学院合肥物质科学研究院应用技术研究所,安徽合肥230031 [2]中国科学技术大学,安徽合肥230026 [3]皖江新兴产业技术发展中心,安徽省生物医学光学仪器工程技术研究中心,安徽铜陵244000
出 处:《光谱学与光谱分析》2016年第10期3215-3221,共7页Spectroscopy and Spectral Analysis
基 金:国家科技支撑计划项目(2015BAI01B04);国家科技支撑计划项目(2013BAH14F01);安徽省自然科学基金项目(1508085QF141);中国科学院安徽光学精密机械研究所所长基金项目(Y33J381141)资助
摘 要:针对皮肤胆固醇无创检测的迫切需求,设计了一种基于微型光谱仪的便携式和智能化的皮肤漫反射光谱实时测量系统。配制毛地黄皂苷—辣根过氧化物酶共聚物溶液,利用毛地黄皂苷可与皮肤胆固醇分子中的羟基特异性结合和辣根过氧化物酶能与TMB试剂(主要成分为3,3’,5,5’-四甲基联苯胺)反应显色的特性,实现皮肤胆固醇的高灵敏和高特异的识别与指示,并通过测量反应后颜色的变化程度来定量皮肤胆固醇的浓度。以与人体皮肤结构相近的猪皮肤为实验对象,采用萃取法获得梯度浓度的胆固醇样本,利用上述光谱测量系统检测样本内的胆固醇浓度来验证该方法的可行性。实验结果显示,相对漫反射率能够区分不同浓度的胆固醇样本,在特征单波长(442,450和463nm)处和特征波段442-500nm内,漫反射率强度因子均可以定量反映样本内的胆固醇浓度,经线性拟合,判定系数R2分别为0.960,0.959,0.958和0.958。研究结果表明,使用漫反射光谱技术可以实现皮肤胆固醇的快速无创检测,将其应用于动脉粥样硬化性疾病风险评估,对于该类疾病的防控具有重要意义。Due to the urgent need for noninvasive detection of skin cholesterol,aportable,intelligent and real-time skin diffuse reflectance spectroscopy measurement system was designed based on a micro-spectrometer.Digitonin-horseradish peroxidase copolymer solution was prepared.According to the properties digitonin binds to the hydroxy of cholesterol molecular specifically and the horseradish peroxidase reacts with TMB color solution(the main component is 3,3',5,5'-tetramethylbenzidine)a color change was produced,by which the skin cholesterol was identified and instructed with high sensitivity and high specificity,and the concentration of skin cholesterol was quantified by measuring the degree of color change.In order to validate the feasibility of this method,pig skin which is similar to human skin was taken as the experimental subject,and cholesterol samples of gradient concentration were achieved through the extraction.After that the spectroscopy measurement system was adopted to detect the cholesterol concentration.The experiment result showed that,relative diffuse reflectance can distinguish the cholesterol samples with different concentrations,and the diffuse reflectance intensity factor can quantity the concentrations of cholesterol at characteristic wavelengths(442,450 and 463nm)and characteristic wavelength band of 442-500nm.Linear fitting curves were obtained with the determination coefficient R2 were 0.960,0.959,0.958 and 0.958,respectively.The study has shown that,using diffuse reflectance spectroscopy technology can realize noninvasive rapid detection of skin cholesterol,and applying it to the risk assessment of atherosclerotic diseases would contribute to the prevention and control of such diseases significantly.
分 类 号:TN29[电子电信—物理电子学]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.249