检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:马勇[1] 王海军[1] 蒋艳芳[1] 王永健[1] 王健[1] 林霖[1] 刘阳[1] 余家阔[1] 敖英芳[1]
机构地区:[1]北京大学第三医院运动医学研究所,北京100191
出 处:《中国运动医学杂志》2016年第10期925-929,共5页Chinese Journal of Sports Medicine
摘 要:目的:以髁间窝外侧壁后软骨缘顶点(the apex of the deep cartilage,ADC)为标志,研究术后CT与镜下评估前交叉韧带(anterior cruciate ligament,ACL)股骨骨道位置时两种方法的一致性。方法:2014年5月至2016年5月,关节镜下前交叉韧带重建患者36例纳入本研究。所有患者术中均依据完好的股骨残端进行中心点定位。屈膝90°,测量ADC至前骨缘的水平距离(L_1)以及与骨道中心点的水平距离(l_1),计算l_1/L_1比值(P_1),同时测量骨道中心点与下骨缘的距离(D_1)。术后在CT片上测量ADC至前骨缘的水平距离(L_2)以及与骨道中心点的水平距离(l_2),计算l_2/L_2比值(P_2),同时测量骨道中心点与下骨缘的距离(D_2)。应用线性回归、Pearson相关和Bland-Altman分析比较镜下评估与CT评估的一致性。结果:P1=44.07%±2.22%(41.1%%~49.5%),D_1=6.2±0.5 mm(5.5~7 mm)。P_2=44.92%±2.27%(40.9%~50.2%),D_2=6.3±0.6 mm(5.1~7.5 mm)。P_1和P_2(r=0.99,P〈0.001)、D_1和D_2(r=0.69,P〈0.001))分别呈正相关,且线性关系显著(P〈0.001)。Bland-Altman图显示一致性较好。结论:以ADC为标志评估ACL股骨骨道位置,术后CT与镜下评估的一致性较好。Objective To examine the consistency between postoperative CT scan and intraoperative arthroscopic measurement in evaluating femoral tunnel position for anterior cruciate ligament(ACL)reconstruction,both using the apex of the deep cartilage(ADC)as the marker. Methods A total of 36 patients undergoing anatomic arthroscopic ACL reconstruction in our institute between May 2014 and 2016 were recruited. The position of the center of femoral tunnel was decided in the complete femoral stub. Then the length from the ADC to the anterior cartilage margin(L1)and to the center of femoral tunnel(l1),as well as the center to the distal cartilage margin(D1)were measured under arthroscopy and on post-operative CT scan(L2,l2 and D2). Moreover,P1 and P2were calculated through l1/L1 and l2/L2. Linear regression,Pearson correlation and Bland-Altman analysis were performed to evaluate the consistency between the two measurements of P and D respectively. Results P1=44.07% ± 2.22%(41.1%-49.5%),D1=6.2 ± 0.5 mm(5.5-7 mm). P2=44.92%± 2.27%(40.9%-50.2%),D2=6.3 ± 0.6 mm(5.1-7.5 mm). A positive correlation was detected between P1 and P2(r=0.99,P0.001),as well as D1 and D2(r=0.69,P〈0.001),both with significances in linear regression(P〈0.001). Bland-Altman plot also showed excellent consistency. Conclusions When using the ADC as the marker,an excellent consistency was found between postoperative CT scan and intraoperative arthroscopic measurements in evaluating femoral tunnel position for ACL reconstruction.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.145