330MW供热机组锅炉排烟余热及水分回收系统  被引量:7

A Flue Gas Waste Heat and Moisture Recovery System for 330 MW Heat Supply Units

在线阅读下载全文

作  者:王金平[1] 邓煜[1] 李斌[1] 安连锁[1] 苗雨旺 张玉斌 王罡 

机构地区:[1]华北电力大学能源动力与机械工程学院,河北保定071003 [2]烟台龙源电力技术股份有限公司,山东烟台264006

出  处:《动力工程学报》2016年第11期920-926,共7页Journal of Chinese Society of Power Engineering

基  金:国家科技支撑计划课题资助项目(2010BAA07B01)

摘  要:针对某330MW燃煤供热机组,采用氟塑料换热器设计了分级布置、二次利用的电站锅炉排烟余热及水分回收系统,按照系统设计方案改造该机组,并在非采暖工况下进行机组性能试验.结果表明:排烟余热及水分回收系统不仅能够充分利用烟气余热、减少脱硫系统水耗,还能回收烟气中的部分水分,降低烟气中颗粒物的浓度,减轻对烟囱的磨损与腐蚀,对电厂安全有效地实现节能减排具有重要意义.For a certain 330 MW coal-fired heat supply unit, a two-stage double utilization system was de- signed for waste heat and moisture recovery from flue gas of the power boiler by making use of fluoroplas- tic heat exchanger. The unit was then retrofitted according to the design plan, for which relevant perform- ance tests were carried out under non-heating conditions. Results show that the flue gas waste heat and moisture recovery system can not only make full use of the waste heat and reduce the water consumption of the desulfurization system, but also recover part of the moisture from the flue gas, which helps to reduce PM concentrations in the flue gas and relieve the wear and corrosion to the chimney, thus achieving effec- tive energy-saving and emission reduction of the power plant.

关 键 词:余热利用 水分回收 氟塑料换热器 性能试验 

分 类 号:TK115[动力工程及工程热物理—热能工程]

 