摘  要:电渗泵是一种液流驱动泵 ,具有装置简单、载流无脉动、流量范围大和驱动电压适中等优点。用含 1mmol/L三乙醇胺和 0 .1mmol/L四丁基溴化铵的乙醇溶液作泵载流 ,采用顺序注射萃取 分光光度法 ,对水样挥发酚进行了测定。有机载流可避免产生界面 ,减小检测干扰。载流添加剂可提高泵流量 ,改善流量稳定性。另外 ,还研究了酚的各种萃取条件。水中酚的检出限为 7μg/L(3σ ,n =11) ;回收率为 92 %~ 94%。Electroosmotic pump is a liquid driving apparatus, which has its advantages of simplified equipment, non-pulsing flow rate, large flow range and moderate working voltage etc.. In this paper, a sequential injection analysis system with an electroosmotic pump, of which ethanol solution containing 1 mmol/L triethanolamine and 0.1 mmol/L tetrabutylammonium bromide was used as the carrier, is proposed for on-line solvent extraction of phenols in water. With the organic solvent as the pump carrier, it can effectively prevent from the detection interference caused by liquid phase interface. Additives of the carrier can enhance and stabilize the pump flow rate. In addition, extraction conditions for phenols were also investigated. The detection limit of phenol was 7 mug/L (3sigma, n = 11) and the recoveries of the method were 92% similar to 94%. The proposed method confirms that electrokinetic flow analysis system can be employed in solvent extraction and organic analysis.

关 键 词:电渗泵 有机载流 顺序注射分析 溶剂萃取 有机分析 水质污染 顺序注射萃取法 测定  

分 类 号:O658[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象