检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑桁[1] 杨春[1] 郭志义[1] 王康[1] 张伟[1] 侯能易[1]
机构地区:[1]四川省医学科学院.四川省人民医院胃肠外科,四川省成都市610072
出 处:《中国组织工程研究》2016年第43期6458-6464,共7页Chinese Journal of Tissue Engineering Research
基 金:四川省卫生厅课题(2012JY0055)~~
摘 要:背景:目前镍钛记忆合金于人造血管、骨科内固定器及矫形支架等方面广泛应用,其生物学特性已得到共识,而加压吻合方法目前已比较成熟。目的:评价应用镍钛记忆合金加压吻合夹行胃肠吻合的有效性和安全性。方法:纳入2013年6月至2016年2月四川省人民医院收治的64例胃空肠吻合患者,所有患者均行远端胃大部切除,按治疗方案均分为2组。加压吻合夹组及对照组分别使用加压吻合夹及一次性钽钉管状吻合器进行胃肠吻合。结果与结论:2组在手术时间、胃空肠吻合时间、术后肠排气时间、进食时间及住院时间等方面均无显著差异(P>0.05)。2组均未发生术中吻合口出血、术后吻合口瘘及胃排空障碍等并发症。加压吻合夹组未发生吻合口狭窄;但对照组出现1例,发生率为3%。加压吻合夹组术后3 d腹部X射线检查显示加压吻合夹均在原位,加压吻合夹于术后9-28 d排出体外,术后6个月复查胃镜,显示胃肠吻合口光滑平整,无充血水肿,组织反应轻。说明应用加压吻合夹进行胃肠吻合安全可靠,可取得与一次性钽钉管状吻合器相同甚至更优的吻合效果,且具有良好的组织相容性,吻合口组织反应轻,不会引起吻合口狭窄等吻合口相关并发症。BACKGROUND: The nickel-titanium memory alloy has been extensively used in blood vessel PrOsthesis, internal fixation, and orthopedic stents, and its biological characters have obtained better understanding. In the meanwhile, the compression anastomosis technology hasbeen mature. OBJECTIVE: To evaluate the safety and efficacy of nickel-titanium memory alloy compression; anastomosis clip (CAC) in gastrointestinal anastomosis. METHODS: Totally 64 patients undergoing distal subtotal gastrectomy from June 2013 to February 2016 in Sichuan.Provincial People's Hospital were divided into two groups. Patients in CAC and controt groups underwent gastrointestinal anastomosis using the CAC and disposable tantalum nail stapler, respectively. RESULTS cONCLUSION: operation Stomach AND .There were no significant differences in the time, jejunum anastomosis time, postoperative exhaust time, eating time and hospitalization time between groups (P 〉 0.05). No complications such as anastomotic bleeding, anastomotic leakage and delayed gastric emptying occurred in the two groups. There was no anastomotic stenosis in the CAC group, but one case in the control group with the incidence of 3%. The abdominal X-ray examination of CAC group at postoperative 3 days showed that the CAC did not move, and was excreted at postoperative 9-28 days. Six months after operation, the gastrointestinal anastomosis was smooth,without congestion and edema under endoscopy, tn conclusion, the CAC for gastrointestinal anastomosis is safe and reliable, achieving the same or even better'results with a disposable tantalum nail stapler, and will not cause anastomotic complications due to good histocompatibility.
关 键 词:胃肠吻合术 镍 钛 组织工程 生物材料 材料相容性 胃肠吻合 加压吻合夹 镍钛记忆合金 远端胃大部切除 组织相容性 手工缝线吻合 机械吻合
分 类 号:R318[医药卫生—生物医学工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.223.97.137