Multiple Endothermic Peaks Resulted from Different Crystal Structures in an Isomorphous Copolymer Poly(3-hydroxybutyrate-co-3-hydroxyvalerate)  被引量:2

Multiple Endothermic Peaks Resulted from Different Crystal Structures in an Isomorphous Copolymer Poly(3-hydroxybutyrate-co-3-hydroxyvalerate

在线阅读下载全文

作  者:You Lv Hao Zhu Min-fang An Hao-jun Xu Li Zhang 王宗宝 

机构地区:[1]Ningbo Key Laboratory of Specialty Polymers,Faculty of Materials Science and Chemical Engineering,Ningbo University,Ningbo 315211,China

出  处:《Chinese Journal of Polymer Science》2016年第12期1510-1522,共13页高分子科学(英文版)

基  金:financially supported by Natural Science Foundation of Zhejiang Province(No.LY15B040003);K.C.Wong Magna Fund in Ningbo University

摘  要:The multiple endothermic peaks of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (P(HB-co-HV)) in differential scanning calorimetry (DSC) results, as one representative phenomenon of polymer with unique cocrystallization behavior, were generally considered as the results of melting/recrystallization. In this study, wide angle X-ray diffraction (WAXD) and small angle X-ray scattering (SAXS) experiments were conducted to analyze the phenomena of multiple endothermic peaks in DSC results. The results of these analyses indicated that the multiple endotherms were mainly caused by different lamellae structures. For P(HB-co-HV) with lower HV content, it was comprised of two structures of HV total exclusion and HV partial inclusion in the crystal lamellae. For P(HB-co-HV) with higher HV content, it was also comprised of two structures of HV total inclusion and HV partial inclusion in the crystal lamellae. However, only structure with HV partial inclusion in the crystal lamellae remained existing after first melting peak for all samples.The multiple endothermic peaks of poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (P(HB-co-HV)) in differential scanning calorimetry (DSC) results, as one representative phenomenon of polymer with unique cocrystallization behavior, were generally considered as the results of melting/recrystallization. In this study, wide angle X-ray diffraction (WAXD) and small angle X-ray scattering (SAXS) experiments were conducted to analyze the phenomena of multiple endothermic peaks in DSC results. The results of these analyses indicated that the multiple endotherms were mainly caused by different lamellae structures. For P(HB-co-HV) with lower HV content, it was comprised of two structures of HV total exclusion and HV partial inclusion in the crystal lamellae. For P(HB-co-HV) with higher HV content, it was also comprised of two structures of HV total inclusion and HV partial inclusion in the crystal lamellae. However, only structure with HV partial inclusion in the crystal lamellae remained existing after first melting peak for all samples.

关 键 词:P(HB-co-HV) Isodimorphism Multiple endotherms Uniform lamellae Sandwich lamellae. 

分 类 号:O631[理学—高分子化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象