GE公司EX2100励磁调节器V/Hz限制动作原因分析  

Cause Analysis of V/Hz Limiter Action for GE EX2100 Excitation Regulators

在线阅读下载全文

作  者:姜志慧 史扬[2] 刘春梅[3] Jiang Zhihui Shi Yang Liu Chunmei(Beijing Taiyanggong Gas-fired Thermal Power Co., Ltd., Beijing 100028, China North China Electric Power Research Institute Co., Ltd., Beijing 100045, China Beijing Jingqiao Thermal Power Co., Ltd., Beijing 100067, China)

机构地区:[1]北京太阳宫燃气热电有限公司,北京100028 [2]华北电力科学研究院有限责任公司,北京100045 [3]北京京桥热电有限责任公司,北京100067

出  处:《发电设备》2016年第6期432-434,共3页Power Equipment

摘  要:详细分析了GE公司EX2100励磁调节器V/Hz限制动作原理,找到了国内某电厂发电机励磁系统频繁误报过激磁限制的原因,确定了GE公司EX2100励磁调节器在设计方面的缺陷,并提出了相应的改进策略。Based on detailed analysis of the operating principle of V/Hz limiter for GE EX2100 excitation regulator, the reason of frequently misstated excitation restriction occurring in the generator excitation system of a domestic power plant was found to be caused by design deficiency in the GE EX2100 excitation regulator, for which corresponding improvement measures were suggested.

关 键 词:发电机 励磁系统 V/Hz限制 低频振荡 PSS调节 

分 类 号:TM761.1[电气工程—电力系统及自动化]

 