循环流化床锅炉深度脱硫系统性能分析与优化建议  被引量:5

Performance Analysis and Optimization of Deep Desulfurization System for Circulating Fluidized Bed Boiler

在线阅读下载全文

作  者:赵宇[1] 宋春然[1] 宁国东 

机构地区:[1]内蒙古电力科学研究院,呼和浩特010020 [2]二连浩特出入境检验检疫局,内蒙古二连浩特011100

出  处:《内蒙古电力技术》2016年第5期40-43,共4页Inner Mongolia Electric Power

摘  要:某电厂2×200MW机组循环流化床锅炉采用炉内脱硫+石灰石—石膏湿法烟气炉外脱硫工艺的深度脱硫方式,深度脱硫系统投运后,运行稳定性差。通过对脱硫系统运行状态进行分析,认为炉外脱硫系统吸收塔内部流场分布不均匀、除雾器除雾效果差、GGH存在堵塞风险、浆液氯离子质量浓度高,以及运行方式存在问题,并就相关问题提出了优化建议。A CFB power plant adopts the way for deep desulfurization, which concluded the desulfurization inside boiler and wet flue gas desulfurization in tail. After the deep desulfurization system put into operation, its operation is not stable. The operation of the desulfurization system are analyzed, find that the furnace desulfurization absorption tower internal flow field distribution is not uniform, the effect of mist eliminator removal is poor, GGH has risk jam, content of chloride ion in slurry is high, and the operation mode exist problem and related problems optimization suggestions are given.

关 键 词:循环流化床锅炉 湿法烟气脱硫 超低排放 除雾器 GGH 氯离子 运行方式 

分 类 号:TM621[电气工程—电力系统及自动化]

 