机构地区:[1]江苏省镇江市中西医结合医院检验科,212003
出 处:《国际检验医学杂志》2016年第22期3137-3138,3141,共3页International Journal of Laboratory Medicine
摘 要:目的探讨免疫透射比浊法测定脂蛋白(a)中,采用2种多点非线性校准方法的测定结果,并确定最合适的校准曲线。方法分别采用Y=aX^2+bX+c和Spline2种方法在AU680生化仪上进行脂蛋白(a)校准。分别检测200例来自临床患者的血清标本和4个标准定值血清,200例临床患者血清按照测定值高低分为5个不同梯度水平,分别统计2组数据的均值(x)、标准差(s),相关系数(r),相对误差(v),偏倚(%)。采用SPSS19.0软件对2组数据偏倚进行统计学分析,以P<0.05表示差异有统计学意义。结果 200例临床患者数据表明,采用Y=aX^2+bX+c曲线时,0~100、>400~600、>600~800mg/L组的脂蛋白(a)测定值比Spline曲线所得数值高;>100~200mg/L组和>200~400mg/L组的脂蛋白(a)测定值相反,Spline曲线所得数值较高。4个标准定值血清的测定结果,Spline曲线所得测定值更接近靶值;而Y=aX^2+bX+c曲线所测定结果中,>100~200mg/L组和>300~400mg/L组所得值偏低,>600~800mg/L组所得值偏高,这与临床患者的血清标本结果一致。结论 Spline曲线更为客观,能更准确地体现免疫透射比浊法测定脂蛋白(a)整个反应过程。Objective To adopt the results detected by the two kinds of multipoint nonlinear calibration method in immune transmission turbidimetry for detecting lipoprotein(a)and to ascertain the most suitable calibration curve.Methods The two kinds of method Y=aX^2+bX+c and Spline were adopted to conduct the lipoprotein(a)calibration in the AU680 biochemical instrument.Two hundreds serum samples from clinical patients and 4standard fixed value serum specimens were detected respectively.The sera from 200 cases of clinical patients were divided into 5different gradient levels.The mean value(x),standard deviation(s),correlation coefficient(r),relative error(v),bias(%)were respectively performed statistics.The biases in the two groups of data were statistically analyzed by using the SPSS19.0software,with P〈0.05 expressing that the difference having statistical significance.Results The data in 200 clinical patients indicated that using the curve of Y=aX^2+bX+c,the lipoprotein(a)detection values in the 0-100mg/L group,400-600mg/L group and 600-800mg/L group were higher than those by the Spline curve;while the detection values in the 100-200mg/L group and 200-400mg/L group were on the contrary,the values obtained by using the Spline curve were higher.In the detection results of 4standard fixed value sera,the values detected by the Spline curve were more close to the target values;while in the results detected by using the curve of Y=aX^2+bX+c,the values in the 100mg/L group and300mg/L group were on the low side and the values in the 600mg/L group were on the high side,which were consistent with the serum specimen results from clinical patients.Conclusion The Spline curve is more objective and can accurately embody the whole reaction process of lipoprotein(a)detection by the immune transmission turbidimetry.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.21.55.178