摘 要:为准确方便快速地测量复杂内筒的液位,设计了超声波液量检测仪。对比采用灵敏度较高的复合压电陶瓷探头,可明显地测出气液回波差异。实验结果表明:100μm后气液的回波包络差别最大,可用来进行气液界面的分辨。以某型复进机为例,验证了复进机倾斜角度在0~30°之间时检测仪测量精度的稳定性。测试结果显示液位高度误差小于1.4 cm,容量误差小于0.15 cm,实装测试表明测试值与实际值具有良好的一致性。In order to measure the liquid level of complex inner drum, an ultrasonic measurement system was designed based on principle of ultrasonic liquid level detection. Composite piezoelectric ceramic probe was adopted. The probe can detect difference of the two echo singles.Experiment resuhs indicate that the difference between echo signal of air and that of liquid after 100 μm is maximum.Measurement accuracy of the ultrasonic measurement system is tested when tilt angle of counterrecoil is less than 30° .The height error of liquid level is less than 1.4 cm and correspondingly volume errnr is less than 0.15 cm.Live-fire test indicates that test value and actual value have good conformity.