Evaluation of the frequency instability limited by Dick effect in the microwave 199Hg+ trapped-ion clock  被引量:1

Evaluation of the frequency instability limited by Dick effect in the microwave ^(199)Hg^+ trapped-ion clock

在线阅读下载全文

作  者:陈义和 佘磊 汪漫 杨智慧 柳浩 李交美 

机构地区:[1]Key Laboratory of Atomic Frequency Standards (KLAFS), Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China [2]State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences, Wuhan 430071, China [3]University of the Chinese Academy of Sciences, Beijing 100049, China

出  处:《Chinese Physics B》2016年第12期189-193,共5页中国物理B(英文版)

基  金:Project supported by the National Natural Science Foundation of China(Grant Nos.11074248 and 11474320)

摘  要:In the microwave 199Hg+ trapped-ion clock, the frequency instability degradation caused by the Dick effect is un- avoidable because of the periodical interrogating field. In this paper, the general expression of the sensitivity function g(t) to the frequency fluctuation of the interrogating field with Nπ-pulse (N is odd) is derived. According to the measured phase noise of the 40.5-GHz microwave synthesizer, the Dick-effect limited Allan deviation of our 199Hg+ trapped-ion clock is worked out. The results indicate that the limited Allan deviations are about 1.75 ×10-13/√τ and 3.03 ×10-13/√τ respectively in the linear ion trap and in the two-segment extended linear ion trap under our present experimental parameters.In the microwave 199Hg+ trapped-ion clock, the frequency instability degradation caused by the Dick effect is un- avoidable because of the periodical interrogating field. In this paper, the general expression of the sensitivity function g(t) to the frequency fluctuation of the interrogating field with Nπ-pulse (N is odd) is derived. According to the measured phase noise of the 40.5-GHz microwave synthesizer, the Dick-effect limited Allan deviation of our 199Hg+ trapped-ion clock is worked out. The results indicate that the limited Allan deviations are about 1.75 ×10-13/√τ and 3.03 ×10-13/√τ respectively in the linear ion trap and in the two-segment extended linear ion trap under our present experimental parameters.

关 键 词:Dick effect 199Hg+ trapped-ion clock Allan deviation 

分 类 号:TM935.11[电气工程—电力电子与电力传动]

 