作 者:王力冉 赵刘军[2] 顾勇杰[2] 于亮[2] 赵华国[1] 洪锦炯 祁峰 陈建清[1] 张吉辉[1]
机构地区:[1]宁波大学医学院,浙江省宁波市315211 [2]浙江省宁波市第六医院脊柱外科,315040 [3]浙江省宁波市李惠利医院骨科,315000
出 处:《中国脊柱脊髓杂志》2016年第11期1012-1017,共6页Chinese Journal of Spine and Spinal Cord
基 金:浙江省自然科学基金资助项目(编号:Y14C100003)
摘 要:目的:通过3D打印技术及骨科数字化技术制作下颈椎前路椎弓根螺钉置钉导航模板,观察模板辅助下置钉的准确性。方法:选取正常成人颈椎湿性标本10具(男、女各5县),将椎前软组织剔除,采用64排薄层CT扫描后获取其DICOM格式数据.导入Mimics软件后三维建模并为颈前路椎弓根螺钉选取理想钉道,设计建立螺钉导航模板后导出其STL数据,通过3D打印机快速打印成型。在导航导板引导下进行下颈椎前路椎弓根螺钉置钉,通过X线及CT评价螺钉的准确性。结果:10具尸体分别于C3~T1每节段置入2枚螺钉,共计120枚,根据螺钉的位置将其分为4级:0纵,螺钉完全存椎弓根内,共115枚;1级,螺钉穿破椎弓根皮质,穿出部分小于螺钉直径的25%,1枚;2级,螺钉穿破椎弓根皮质,穿出部分为螺钉直径的25%~50%,3枚;3级,螺钉穿出椎弓根部分大于螺钉直径的50%,1枚.5枚穿破椎弓根皮质背2枚穿破椎弓根内侧皮质,3枚穿破外侧皮质,总体准确性为95撂%。结论:在湿性尸体颈椎标本j=应用3D打印及骨科数字化技术制作的导航模板辅助行下颈椎前路椎弓根螺钉置钉的准确性高,为临床应用提供了依据。Objectives: To study the accuracy of template-assisted anterior cervical pedicle screw placement that based on 3D printing technique and digital orthopedics technique. Methods: Ten normal adult e, ervical specimens were included, 5 males and 5 females. The anterior soft tissue of vertebra was removed before CT scan evaluation, and the data were imported to Mimics software by DICOM format. Cervical vertebra was 3D modeled and ideal trajectory was designed for anterior cervical pediele screw, the STL data were imported to 3D printer after the establishment of navigation template model. Finally, drill guidance template was material- ized by stereolithography apparatus. Anterior pediele screws were placed under the guidance of navigation templates and the accuracy was assessed by postoperative CT scan and X-ray. Results: 120 anterior pedicle screws in total were inserted in 10 specimens on both sides from C3 to TI. All the screws were divided into 4 levels according to their placements: grade 0, showing a perfect position without involvement of pedicle conical bone(115); grade 1, less than 25% of screw diameter violation(l); grade 2, 25% to 50% of screw diameter violation(3); grade 3, more than 50% of screw diameter violation. The accuracy rate of screws placement was 95.8%. Conclusions: Individualized navigation guidance template which based on 3D printing and digital orthopedics technique, can effectively improve the accuracy of anterior cervical pedcile screw placement and reduce the risk of intraoperative injury, and shows a promising prospect for clinical application.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:18.226.214.156