35kV变电所SVC分段自动并网技术的应用  

Application of SVC Automatic Grid Connected Technology in 35kV Substation

在线阅读下载全文

作  者:王庆春 张修辉 王楠 代伟 牛钢 

机构地区:[1]兖矿集团南屯煤矿,山东邹城273515

出  处:《煤矿机电》2016年第6期104-105,共2页Colliery Mechanical & Electrical Technology

摘  要:根据煤矿节能的要求,结合现有无功补偿和谐波治理技术,提出了一种实现煤矿无功补偿、谐波治理的改进及应用方法,即增加设备、联络开关的检测位置,设定相应控制程序,使无功补偿系统能配合使用。经在南屯煤矿实际运行后得知,该自动并网技术既提高了效率,又改善了电网质量,取得了良好的效果。According to the requirements of coal mine energy saving, combined with existing reactive power compensation and harmonic control technology, put forward a coal mine to achieve reactive power compensation, harmonic governance improvement and application of the method, that is, to increase the equipment, contact switch position detection, set the corresponding control program, the reactive power compensation system can be used in conjunction with. The automatic grid technology in Nantun coal mine used in actual operation. It can not only improve the efficiency, but also improve the quality of the power grid, and achieved good results.

关 键 词:节能 无功补偿 并网技术 

分 类 号:TM714.3[电气工程—电力系统及自动化]

 