检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:周广杰[1] 高永芬[1] 张乐川[1] 张书迎[1] 高振宝[1]
机构地区:[1]山东电力工程咨询院有限公司
出 处:《电站系统工程》2016年第6期13-16,共4页Power System Engineering
摘 要:GB50660-2011《大中型火力发电厂设计规范》推荐的超超临界机组再热蒸汽系统压力损失系数为7%~9%,但二次再热机组的再热系统压力损失系数的取值范围值得进一步分析研究。根据设计参数选取了一系列不同直径、壁厚的管道规格,利用AFT流体分析软件对某百万千瓦二次再热机组再热蒸汽系统的压力损失进行了模拟计算,并依据汽轮机入口压力对热耗的影响,对管道投资和收益进行经济性对比分析。对于百万千瓦二次再热机组而言,一级再热系统的压力损失系数宜为6.7%~7.0%,二级再热系统的压力损失系数宜为8.29%~9.13%。The advised reheat steam system pressure loss coefficient of ultra-supercritical unit is 7% to 9% by Code for Design of Fossil Fired Power Plant GB50660-2011, which is worth to be further studied for double reheat thermal power plant. The reheat steam system pressure loss of one 1000 MW double reheat thermal power plant was simulated by AFT fluid analysis software based on a series of pipes with different diameter and wall thickness selected by design parameters. Then the initial investment and profit economy were calculated and compared according to the effect of steam turbine inlet pressure on heat consumption. For 1000 MW double reheat thermal power plant, the reasonable pressure loss coefficient is 6.7% to 7.0% for the first stage reheat steam system, and is 8.29% to 9.13% for the second stage reheat steam system.
关 键 词:百万千瓦 二次再热机组 再热蒸汽系统 压力损失系数
分 类 号:TK212[动力工程及工程热物理—动力机械及工程]