检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]江苏盛立环保工程有限公司,江苏南京210019
出 处:《环境科技》2016年第6期34-37,共4页Environmental Science and Technology
摘 要:以某总磷(TP)超标的中水水源景观水作为研究对象,采用单独絮凝和氧化絮凝对其除磷小试,考察了氧化絮凝中芬顿除磷的各因素及其一级交互作用影响显著度。结果表明,芬顿除磷各因素中硫酸亚铁投加量(M1)和初始pH值为显著影响因素,反应时间(t)和双氧水投加量(M2)为非显著影响因素,以最优条件M1=650 mg/L,pH值=6.0,t=45 min,M2=0.40 mL/L应用工程,出水ρ(TP)<0.5 mg/L,满足GB/T 18921—2002《城市污水再生利用景观环境用水水质标准》。Thescenicwaterfromrecycledwaterresourcewiththeoverprooftotalphosphorus (TP) value had been studied. The signal coagulation and the oxidation coagulation had been used for phosphorus removal in lab-scale experiment. The factors of Fenton removal TP in oxidation coagulation and their first-order interaction effect degree were investigated. The results showed that the dosage of FeSO4 (M1) and the initial pH were two significant factors, yet the reaction time (t) and the dosage of H202 (M2) were two non-significant factors, and the optimal conditions were obtained at M1 of 650 mg/L, pH of 6.0, t of 45 min and M2 of 0.40 mL/L. The TP〈 0.5 mg/L of effluent was also achieved at the best conditions in practical engineering, and met the discharge standard of The reuse of urban recycling water -Water quality standard for scenic environment use (GB/T 18921-- 2002).
分 类 号:X7[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.42