检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]合肥工业大学教育部光伏系统工程研究中心,安徽合肥230009
出 处:《电器与能效管理技术》2016年第23期59-65,共7页Electrical & Energy Management Technology
基 金:国家863高技术基金项目(2011AA05A107);广东省引进创新科研团队计划资助(2011N015)
摘 要:为使有源电力滤波器(APF)直流侧电压顺利升至设定值并安全并网,介绍了采取软起动的必要性;同时分析了目前软起动的方法,并将其划分为3大类:外加电源法、外加限流电阻法、智能控制算法。最后,比较了每种起动方法的优缺点,为工程应用中选择合适的APF起动方法提供指导,避免出现重复起动、烧坏设备等情况,具有一定的实用价值。This paper firstly introduced the necessity of adopting soft start to make the DC side voltage of APF rise to the setted value. Then,the method of soft start was analyzed, and it is divided into three categories: external power supply method, external current limiting resistance method and intelligent control algorithm, and each category has a fine classification. At last,the advantages and disadvantages of each method were compared,and it is helpful to select the suitable APF starting method in engineering application. It can avoid some situations such as repeated priming, burning equipments and has a practical value.
关 键 词:有源电力滤波器 直流侧电压 软起动 限流电阻 智能控制
分 类 号:TM762[电气工程—电力系统及自动化]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.36