检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:郑明光[1] 生金峰[2,3] 吴学纲[2,3] 王永桃[2,3] 隋大千 姬茹一 魏星[2,3] 郑晓荣[2,3]
机构地区:[1]中海石油炼化有限责任公司惠州炼油分公司,广东惠州516081 [2]甘肃蓝科石化高新装备股份有限公司,甘肃兰州730070 [3]机械工业上海蓝亚石化设备检测所有限公司,上海201518
出 处:《石油化工设备》2017年第1期20-23,共4页Petro-Chemical Equipment
摘 要:通过实验研究了以盐硝混酸分解试样、氯化亚锡为还原剂、硫氰酸钠为显色剂,在酸性条件下通过测其吸光度测定高钼合金钢中钼质量分数的方法。该方法可缩短高钼合金钢中钼质量分数的测定分析周期,提高测量的准确度,操作简便,具有较好的实用性。The method to determine the molybdenum in high molybdenum alloy steel is studied by experiment. In the method, the specimen is dissolved in a mixed acid of hydrochloric acid and nitric acid, using the SnCl2 as reducing agent, the NaSCN as chromogenic reagent, the content of molybdenum is determined by measuring the absorbance in acidic conditions. The method can not only shorten the analysis cycle, improve the accuracy, but also is easy and simple to handle. So it has better practicability.
分 类 号:TQ050.1[化学工程] TG142.15[一般工业技术—材料科学与工程]