检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:毛慧[1,2] 姚军[3] 吴晶[1,2] 冯慧颖[1,2]
机构地区:[1]江苏省泰州市环境监测中心站,江苏泰州225300 [2]江苏省土壤有机物重点实验室 [3]泰州市环境保护局海陵分局
出 处:《现代农业科技》2017年第2期168-169,176,共3页Modern Agricultural Science and Technology
摘 要:根据不同人员在不同时间对水中铜的质控样品进行测量得到30组数据,利用Top-down技术控制图法评定ICP-MS方法测定水中铜的不确定度。方法依据是《水质65种元素的测定电感耦合等离子体质谱法》(HJ700—2014),测定质量浓度为40.0μg/L的质控样品,测定均值为40.2μg/L,通过评定不确定度为1.60μg/L。Copper in water samples was determined for quality control by different people in different time. According to 30 sets of data obtained,the uncertainty of ICP-MS method determination of copper in water was evaluated by Top-down technical control chart method. The method was based on ″Water quality-Determination of 65 elements-Inductively Coupled Plasma-mass Spectrometry ″(HJ700-2014). Copper quality control samples(40.0 μg/L)were analyzed,and the average result was 40.2 μg/L. Measurement uncertainty of copper in water by ICP-MS was 1.60 μg/L.
关 键 词:铜 Top-down技术控制图法 不确定度 ICP-MS
分 类 号:X830.5[环境科学与工程—环境工程]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.74