检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:尤坤[1] 张玉钧[1] 刘国华[1,2] 陈晨[1] 高彦伟[1] 何莹[1] 张恺[1] 贺春贵[1] 鲁一冰 刘文清[1] YOU Kun ZHANG Yujun LIU Guohua CHEN Chen GAO Yanwei HE Ying ZHANG Kai HE Chungui LU Yibing LIU Wenqing(Key Laboratory of Environment Optics and Technology, Anhui Institute of Optics and Fine Mechanics Chinese Academy of Sciences, Hefei 230031, China University of Science and Technology of China, Hefei 230026, China)
机构地区:[1]中国科学院安徽光学精密机械研究所中国科学院环境光学与技术重点实验室,安徽合肥230031 [2]中国科学技术大学,安徽合肥230026
出 处:《大气与环境光学学报》2017年第1期43-49,共7页Journal of Atmospheric and Environmental Optics
基 金:国家863计划;2014AA06A503;国家重大科学仪器设备开发专项;2012YQ22011902~~
摘 要:机动车排放的总碳氢化合物(total hydrocarbons,THC)是造成雾霾、光化学烟雾的重要原因之一,在城市大气污染的调查和影响人类健康的研究中,THC是必须的监测目标之一。着重开展了基于氢火焰离子化检测(hydrogen flame ionization detector,FID)的机动车尾气THC测量系统的设计和对比实验。主要介绍了FID测量THC的工作原理,根据FID的测量原理设计了机动车尾气THC测量模块。并根据离子化信号检测需求设计了微电流放大电路,满足大范围、高精度微电流信号检测的要求,获得了检测器对THC的响应峰信号。还对测量得到的THC色谱峰信号进行定性和定量的分析,通过标准曲线法计算了THC的浓度。最后结合美国的SENSORS-FIDTHC分析仪开展了对比实验,结果表明研发的THC测量模块检测的浓度偏高,测量偏差约为4.44%~8.43%,判断此系统误差主要因为O_2峰干扰。Total hydrocarbons (THC) of vehicle emissions is the major cause of haze and photochemical smog, so THC monitoring must be one of the goals in the investigation of urban air pollution and research of effects on human health. The design of the THC measurement system based on hydrogen flame ionization detector (FID) for vehicle exhaust is developed and comparative experiments are carried out. The working principle of the FID for measuring THC is introduced, and the THC measurement module of vehicle exhaust is designed according to the measuring principle of FID. A micro-current amplifier circuit is designed for detecting the ion signals to meet a wide range, high-precision and micro-current signal testing requirements, and the peak signal of the THC is obtained. Moreover, the THC peak signals are analyzed qualitatively and quantitatively. The concentration of the THC are calculated by standard curve method. The comparative experiments are carried out by using SENSORS-FID THC analyzer of the United States, and the results show that the measurements of the THC measurement module is higher, and the measurement error is about 4.44%~8.43%, this systematic error is primarily caused by oxygen peak interference
关 键 词:氢火焰离子化检测 总碳氢化合物 微电流放大电路 标准曲线法
分 类 号:X734.2[环境科学与工程—环境工程] X831
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.28