检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:杨杰 杨耀[2] 杨勇 YANG Jie YANG Yao YANG Yong(Huadian International Laizhou Power Generation Co., Ltd. , Laizhou 261400, China Shanghai Power Equipment Research Institute, Shanghai 200240, China)
机构地区:[1]华电莱州发电有限公司,山东莱州261400 [2]上海发电设备成套设计研究院,上海200240
出 处:《锅炉技术》2017年第1期19-22,37,共5页Boiler Technology
摘 要:超临界压力直流锅炉炉膛水冷壁倾斜管内壁对工质的对流换热系数及对水冷壁管的安全运行尤为重要,为此对某1 000 MW超临界压力塔式直流锅炉螺旋水冷壁进行了实炉试验测量,计算出螺旋管圈水冷壁管内壁与工质间的对流换热系数,并以此为据,拟合出计算超临界压力下螺旋水冷壁管对流换热系数的计算公式,并对该炉型水冷壁管超温现象进行了分析,为水冷壁的安全运行提供了参考依据。The leaning tube internal convective heat transfer coefficient of water wall tube in supercritical pressure once-through boiler is important for safe operation of the water wall, so the experimental tests were done on spiral tube of one 1 000 MW supercritical pressure once- through tower-type boiler, and the convective heat transfer coefficient between spiral tube and the fluid was calculated, then the formula of convective heat transfer coefficient of spiral tube under supercritical pressure was fitted. And the overheating of water wall in this type boiler was analyzed, and the reference was provided for safe operation of water wall.
分 类 号:TK223.31[动力工程及工程热物理—动力机械及工程]