低电流电絮凝法去除废水中重金属离子的研究  被引量:8

Removal of Heavy Metal Ions from Wastewater by Low Current Electrocoagulation Technology

在线阅读下载全文

作  者:周好磊 李少林[1] 魏宏斌[1] 盛一楠 陈良才 

机构地区:[1]同济大学环境科学与工程学院,上海200092 [2]上海中耀环保实业有限公司,上海200092

出  处:《中国给水排水》2017年第5期85-88,共4页China Water & Wastewater

摘  要:以铁板为电极,通过间歇试验和连续流试验分析低电流电絮凝法去除重金属离子Cu^(2+)、Zn^(2+)、Pb^(2+)的影响因素及效果。结果表明,在电流密度为0.42 A/dm2、电解时间为10 min、极板间距为14 mm、废水电导率为1.0 m S/cm、电絮凝反应器出水p H调节值为8.5条件下,对Cu^(2+)、Zn^(2+)、Pb^(2+)的去除率分别达到99.8%、98.6%和99.7%以上,处理后该3种重金属离子的浓度均远低于《污水综合排放标准》(GB 8978—1996)一级排放标准。Using the iron plate as electrode in batch experiment and continuous flow experiment, the influence factors and removal efficiency of heavy metals, including CuE + , Zn2 + and Pb2 + , of the low current eleetrocoagulation technology were analyzed. Results showed that removal efficiencies of Cu2+ , Zn2 + , Pb2 + were 99.8% , 98.6% , 99.7% respectively, when the current density was 0.42 A/dm2, the time of the electrolytic treatment was 10 min, the distance between the electrode plates was 14 ram, the conductivity was 1.0 mS/cm, and adjusted value of effluent pH was 8.5. Concentrations of Cu2 + , Zn2 + and Pb2+ in effluent were much lower than the requirements in the national standard.

关 键 词:电絮凝 CU2+ Zn2+ PB2+ 连续流试验 

分 类 号:X703[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象