检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]福州大学环境与资源学院,福州350116 [2]福建省生物质资源化技术开发基地,福州350116
出 处:《工业用水与废水》2017年第1期28-32,共5页Industrial Water & Wastewater
基 金:福建省企业技术创新(省属)专项资金补助项目(中小城镇生活垃圾的处理处置及垃圾渗滤液的资源化利用)
摘 要:采用混凝沉淀-Fenton氧化处理垃圾渗滤液生化处理出水,通过单因素试验研究了混凝沉淀和Fenton氧化中各因素对去除CODCr的影响,试验结果表明,最佳混凝试验工艺条件为:复合混凝剂比例n(无机组分)∶n(有机组分)为4.0∶1、p H值为8.5、混凝剂投加量0.6 g/L,CODCr的去除率可达到88.6%。Fenton氧化阶段,当体系p H值为4.0、H2O2投加量为16 mg/L、Fe SO4·7H2O投加量为6 g/L、反应时间为110 min时,CODCr去除率高达95.9%。Using coaguolation sedimentation-Fenton oxidation process to treat biochemical effluent of landfill leachate, the factors that influencing CODcr removal were studied through single factor test. The results of the test showed that, the optimal condition for coagulation test was as follows: the ratio of n(inorganic component) to n(organic component) was 4.0 : l, the pH value was 8.5, the coagulant dosage was 0.6 g/L, the removal rate of CODcr could reach 88.6%. In the process of Fenton oxidation, when the system pH value was 4.0, the dosage of H202 and FeSO4·7H2O were 16 mg/L and 6 g/L respectively, the reaction time was 110 min, the removal rate of CODcr reached 95.9%.
分 类 号:X703.1[环境科学与工程—环境工程]