检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:江剑峰[1] 朱彬若[1] 郜登科[2] 杨喜军[2]
机构地区:[1]国网上海市电力公司电力科学研究院,上海200437 [2]上海交通大学电力传输与功率变换控制教育部重点实验室,上海200240
出 处:《电器与能效管理技术》2017年第4期59-63,共5页Electrical & Energy Management Technology
摘 要:在综合分析角形结构链式静止同步补偿器(STATCOM)电流关系、桥臂电流负序分量和桥臂有功功率的基础上,基于桥臂电容电压平衡控制、负荷电流负序分量和系统线电压相角,提出了一种共同生成环流参考值的新方法。经MATLAB/Simulink仿真分析,所提方法的共同生成环流参考值可以有效地实现角形结构链式STATCOM。The cascade static synchronous compensator( STATCOM) with delta configuration is usually used to compensate negative sequence currents,and its reference value of circulating currents determines the stabilization of the capacitor voltages. Based on a comprehensive analysis of the current relationship of the cascade STATCOM with delta configuration,the negative sequence current components as well as active power of the bridge arms,the reference value can be mutually produced by the bridge arm capacitor voltage balancing control,load current negative sequence component and system line-to-line voltage phase angle. The simulation results by MATLAB /Simulink prove the feasibility and effectiveness of the control method by using this mutually produced reference values for the cascade STATCOM with delta configuration.
关 键 词:链式STATCOM 角形结构 负序电流补偿 环流参考值
分 类 号:TM76[电气工程—电力系统及自动化]