检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:张岗[1] 朱美春[2] 贺拴海[1] 王翠娟[3] ZHANG Gang ZHU Mei-chun HE Shuan-hai WANG Cui-juan(School of Highway, Chang'an University, Xi'an 710064, Shaanxi, China School of Civil Engineering, Shanghai Normal University, Shanghai 201418, China School of Engineering Machinery, Chang'an University, Xi'an 710064, Shaanxi, China)
机构地区:[1]长安大学公路学院,陕西西安710064 [2]上海师范大学建筑工程学院,上海201418 [3]长安大学工程机械学院,陕西西安710064
出 处:《中国公路学报》2017年第2期77-85,共9页China Journal of Highway and Transport
基 金:国家自然科学基金项目(51308056;51108265);国家留学基金委项目(201406565013);交通运输部交通建设科技项目(2011 318 812 970);中央高校基本科研业务费专项资金项目(310821172003)
摘 要:为了给出火灾下预应力混凝土薄腹梁的破坏准则,针对火灾下预应力混凝土T形截面梁桥的破坏问题,研究火灾高温传导模式和热传导混合边界条件,设定预应力混凝土T形截面梁的火灾作用模式,分析其温度场分布状态,并给出预应力混凝土T形截面梁变形破坏的计算细节和判定条件。采用热力场耦合计算方法,研究不同火灾模式下预应力混凝土T形截面梁桥的破坏模式,跟踪不同火灾模式下预应力混凝土T形截面梁的梁肋变形和翼缘板变形路径。研究结果表明:仅预应力混凝土T形截面梁的梁肋受火时,梁肋的破坏时间和翼缘板的破坏时间相同,其耐火时间相对于其他受火模式较长;预应力混凝土T形截面梁下部单侧受火时,T形截面梁的截面产生显著畸变,受火侧翼缘板的破坏先于梁肋的破坏,破坏时间提前10min;预应力混凝土T形截面梁下部和顶部均受火时,两侧翼缘板的破坏均先于梁肋的破坏,破坏时间提前10min;预应力混凝土T形截面梁顶板受火或整体受火时,T形截面梁的破坏时间相对较早,为40~60min,顶板受火对预应力混凝土T形截面梁的耐火极限影响显著,该研究可为预应力混凝土薄腹梁的抗火性能研究和抗火设计提供理论依据。To provide failure criterion of prestressed concrete thin-web grider exposed to fire,aimed at the failure problem of prestressed concrete T girder exposed to fire,the heat transfer model and the combined boundary condition of thermal conduction were investigated,the fire exposure model of prestressed concrete T girder was set,the temperature distribution in girder section of prestressed concrete T girder was analyzed,and the calculation detail and the decision condition of deformation damage in prestressed concrete T girder were proposed.The thermomechanical coupling method was applied,to investigate the failure model of prestressed concrete T girder exposed to fire,and trace the deformation path of rib and flange plate in prestressed concrete T girder under different fire models.The results show that when the rib is only exposedto fire,the failure time of rib and flange plate is identical,and fire-resistance time is relatively longer than other fire models.When the single side under prestressed concrete T girder is exposed to fire,there is obvious distortion of T grider.The damage of flange plate exposed to fire is prior to the damage of rib,about 10 min in advance.When the top of the flange plate and the bottom of T girder are all exposed to fire,the failure time of bilateral flange plates is 10 min earlier than that of rib.When the top of the flange plate or the girder is exposed to fire,the failure time of T girder is relatively earlier than that of other fire models,between 40 min and 60 min,and the top of flange plate exposed to fire has an obvious influence on fire resistance of prestressed concrete T girder.This research may provide a theoretical basis for fire resistance performance research and design of prestressed concrete thin-web girder.
关 键 词:桥梁工程 混凝土T形截面梁 有限元方法 破坏模式 预应力 火灾
分 类 号:U448.213[建筑科学—桥梁与隧道工程]