南京地区地埋管换热器的实测与分析  被引量:1

ACTUAL TEST AND ANALYSIS OF GROUND HEAT EXCHANGER IN NANJING AREA

在线阅读下载全文

作  者:汤盼城 凌舒 杨阳[1] 崔全琦 龚延风[1] 

机构地区:[1]南京工业大学城市建设与安全工程学院,南京210009 [2]南京市住房和城乡建设委员会,南京210009 [3]扬州三盛房地产开发有限公司,扬州225000

出  处:《太阳能学报》2017年第2期378-385,共8页Acta Energiae Solaris Sinica

基  金:南京市住房与城乡建设委员会科研项目(2012)

摘  要:对南京地区6个实际办公类、医院类和住宅类建筑中土壤源热泵系统的运行参数进行一个夏季和冬季的连续测试,从地埋管出水温度和传热热阻2个方面进行分析评价,结果表明:土壤源热泵冬季制热效率高,而夏季制冷效率存在较大差异。多数地埋管初始换热热阻高于钻孔内理想换热热阻,热泵机组的运行管理比较粗放,需要大力提升管理水平。The summer and winter continuous tests for ground-source heat pump systems operating in six actual offices, hospitals and residential buildings in Nanjing area were carried out to get operating parameters, and outlet water temperature of buried pipe and heat transfer resistance were analyzed and evaluated. The results show that the heating efficiency of ground-source heat pump system is relatively high in winter, however, there is larger diversity for the refrigerating efficiency in summer. The initial heat transfer resistances of numerous buried pipes are higher than ideal heat transfer resistance in bore, the operation management of heat pump system is relatively extensive, the management level needs improving energetically.

关 键 词:土壤源热泵 地埋管 换热效果 施工质量 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 