检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]宁夏农业勘查设计院,宁夏银川750002 [2]宁夏农林科学院农业经济与信息技术研究所,宁夏银川750002
出 处:《宁夏农林科技》2016年第12期50-51,62,共3页Journal of Ningxia Agriculture and Forestry Science and Technology
摘 要:本实验对比了四苯硼酸钾重量法和火焰光度计法测定复混(合)肥料中氧化钾的含量的差别。结果表明:1四苯硼酸钾重量法测得的结果明显高于火焰光度法。2四苯硼酸钾重量法的沉淀、烘干时间较长,回收率为97.6%~99.0%,精密度0.02%~0.5%;火焰光度法仅需0.5 h,精密度〈0.5%,回收率97.8%~98.3%,2种方法均可满足分析要求。32种方法测定结果可通过回归方法 Y=1.2 X修正,误差范围为0.01%~0.11%。The experiment was conducted to compare the potassium oxide content differences between potassium tetraphenylborate gravimetric method and flame photometer method in compound fertilizer.The results showed that the measured values by potassium tetraphenylborate gravimetric method were significantly higher than those measured by flame photometer method.The potassium tetraphenylborate gravimetric method had longer setting and drying time with recovery ratio of 97.6% ~ 99.0%and precision of 0.02% ~ 0.5%; while the flame photometer method had the setting and drying time of 0.5 h with the precision of less 0.5% and the recovery ratio of 97.8% ~ 98.3%.Both of the two methods could meet analysis requirements.The analysis results can be amended by error-correction model Y=1.2X with error range of 0.01%~0.11%.
关 键 词:重量法 四苯硼酸钾 火焰光度法 国家标准方法 氧化钾
分 类 号:TQ444[化学工程—化学肥料工业]