Thermoluminescence Kinetic Parameters of TLD-600 and TLD-700 after 252Cf Neutron+Gamma and 90Sr-90Y Beta Radiations  

Thermoluminescence Kinetic Parameters of TLD-600 and TLD-700 after ^(252)Cf Neutron+Gamma and ^(90)Sr-^(90)Y Beta Radiations

在线阅读下载全文

作  者:S.Iflazoglu V.E.Kafadar B.Yazici A.N.Yazici 

机构地区:[1]University of Gaziantep,Department of Engineering Physics,Gaziantep 27310,Turkey

出  处:《Chinese Physics Letters》2017年第1期120-124,共5页中国物理快报(英文版)

基  金:Supported by the University of Gaziantep Scientific Research Projects Coordination Unit under Grant No MF.14.16

摘  要:The thermoluminescent(TL) properties such as glow curve structure, relative thermoluminescence sensitivity,dose response linearity of lithium fluoride thermoluminescent dosimeters 6 LiF:Ti,Mg(TLD-600) and 7 LiF:Ti,Mg(TLD-700) are investigated after irradiationCf neutron+gamma andSr-Y beta sources at room temperature and then the obtained results are compared. The kinetic parameters, namely the order of kinetics b,activation energy Ea and the frequency factor s,are calculated using the computerized glow curve deconvolution(CGCD) program. The effect of heating rate on the glow curves of dosimeters is also investigated. The maximum TL peak intensities and the total area under the glow curves decrease with the increasing heating rate. There is no agreement with the kinetic parameters calculated by the CGCD program for both radiation sources.The thermoluminescent(TL) properties such as glow curve structure, relative thermoluminescence sensitivity,dose response linearity of lithium fluoride thermoluminescent dosimeters 6 LiF:Ti,Mg(TLD-600) and 7 LiF:Ti,Mg(TLD-700) are investigated after irradiation ^(252)Cf neutron+gamma and ^(90)Sr-^(90)Y beta sources at room temperature and then the obtained results are compared. The kinetic parameters, namely the order of kinetics b,activation energy Ea and the frequency factor s,are calculated using the computerized glow curve deconvolution(CGCD) program. The effect of heating rate on the glow curves of dosimeters is also investigated. The maximum TL peak intensities and the total area under the glow curves decrease with the increasing heating rate. There is no agreement with the kinetic parameters calculated by the CGCD program for both radiation sources.

关 键 词:TLD Cf Neutron+Gamma and Sr 

分 类 号:TL818.1[核科学技术—核技术及应用]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象