避难硐室监控系统用备用电源的设计  被引量:4

Design of standby power supply for monitoring and control system for refuge chamber

在线阅读下载全文

作  者:刘亚辉[1,2] 

机构地区:[1]瓦斯灾害监控与应急技术国家重点实验室,重庆400037 [2]中煤科工集团重庆研究院有限公司,重庆400039

出  处:《煤炭工程》2017年第3期19-21,25,共4页Coal Engineering

基  金:中煤科工集团重庆研究院有限公司自立项目(CQ1315)

摘  要:为保证避难硐室监控系统的备用电源应能在交流停电的情况下使系统正常工作不低于96h,根据监控系统设备种类多、单个设备功耗较小的特点,设计出一种本质安全型备用电源。详细介绍了该备用电源的硬件设计和软件设计,其中硬件设计包括:备用电池组的设计、充电电路设计、输出保护电路设计、电源管理电路设计。该电源可减少能量传递过程中的损耗,提高电池的使用效率,并采用本安技术减轻了产品重量及安装难度,提高了产品的可靠性。To ensure at least 96 hours normal functioning of standby power supply during the blackout in coal mine refuge chamber,according to the various kinds of equipment monitoring system,and the low power consumption of single equipment,an intrinsically safe standby power supply was designed.The hardware and software design was introduced in detail,the hardware design comprised standby battery pack,charging circuit,output protection circuit and power management circuit.The power supply can reduce the loss of the energy transfer process,improve use efficiency of the battery,reduce the weight and installation difficulty,and improve the reliability.

关 键 词:避难硐室 监控系统 镍氢电池 本质安全 低功耗 